Switch Model Switch Power Consumption (No PoE Load) PoE Power Budget DC Input Voltage Range TI-PE50 2.24W 90W 48 – 56V TI-PE80 5.76W 200W 48 – 56V TI-PG541 10W 120W 48 – 57V TI-PG62 5.76W 120W 48 – 56V TI-PG62B 5.76W 60 – 120W 12 – 56V TI-PG50 5.76W 120W 48 – 56V TI-PG80 5.76W 200W 48 – 56V TI-PG102 5.67W 240W 48 – 56V TI-PG160 13W 240W 48 – 56V TI-UPG62 (V1.0R) 5.76W 240W 48 – 56V TI-UPG62 (V2.0R) 6.2W 240W 52 – 56V TI-PG162 13W 240W 48 – 56V TI-PG80B 5.
ENGLISH FRANÇAIS DEUTSCH ESPAÑOL Power Supply Model Max. Power Supplied DC Output Type TI-M6024 60W 24V / 2.5A DIN-Rail TI-S12024 120W 24V / 5A DIN-Rail TI-S12048 120W 48V / 2.5A DIN-Rail TI-S24048 240W 48V / 5A DIN-Rail TI-S48048 480W 48V / 10A DIN-Rail 48VDC3000 160W 48V / 3.
DL OK
ESPAÑOL DEUTSCH FRANÇAIS ENGLISH
ENGLISH FRANÇAIS DEUTSCH ESPAÑOL GND +V1- GND +V2- PW1 PW2 1A@24V V1+ V1+ DL OK V1- V2+ V2- DL DL OK OK DL OK V1- V2+ V2-
ENGLISH FRANÇAIS DEUTSCH ESPAÑOL TI-PG541 PWR RPS Status Description Solid Green Power is Connected Off Power is Not Detected Solid Green Power is Detected Off Power is Not Detected Solid Red Either PWR or RPS is disconnected (Based on DIP switch settings) Off Both PWR and RPS are connected and powered, Dependent on DIP switch settings ALM LNK/ACT 1000M 1000M SFP POE+, 1, 2, 3, 4 Solid Green Connected Flashing Green Data Transmitting / Receiving Off No Connection Solid Green Con
TI-UPG62 PW1 PW2 ERR LNK SPD SFP (F5,F6) POE (P1, P2, P3, P4) Status Description Solid Green Power is Connected Off Power is Not Detected Solid Green Power is Detected Off Power is Not Detected Solid Amber Connected only PW1 or PW2 Off Both PW1 and PW2 are connected and powered Solid Green Connected Flashing Green Data Transmitting / Receiving Off No Connection Solid Amber Connected at 1000M Off Connected at 10/100M Solid Green Connected Flashing Green Data Transmitting / Re
ENGLISH TI-PG62 FRANÇAIS PW1, P1 PW2, P2, RPS ESPAÑOL DEUTSCH PW3 RLY LNK SFP (F5, F6) PoE Status Description Solid Green Power is Detected Off Power is Not Detected Solid Green Power is Detected Off Power is Not Detected Solid Amber Power is Detected Off Power is Not Detected Solid Amber Connected only PW1, PW2, PW3 Off Two of the PW1, PW2, PW3 are connected and powered Solid Green Connected Flashing Green Data Transmitting / Receiving Off No Connection Solid Green Conne
TI-PG62B PW1 PW2 ERR LNK SPD SFP (F5, F6) POE (P1, P2, P3, P4) Status Description Solid Green Power is Detected Off Power is Not Detected Solid Green Power is Detected Off Power is Not Detected Solid Amber Connected only PW1 or PW2 Off Both PW1 and PW2 are connected and powered Solid Green Connected Flashing Green Data Transmitting / Receiving Off No Connection Solid Amber Connected at 1000M Off Connected at 10/100M Solid Green Connected Flashing Green Data Transmitting / Re
ENGLISH TI-PG102 FRANÇAIS P1 P2 DEUTSCH P3 RLY ESPAÑOL LINK, LNK/ACT SFP (F9, F10) PoE Status Description Solid Green Power is Detected Off Power is Not Detected Solid Green Power is Detected Off Power is Not Detected Solid Amber Power is Detected Off Power is Not Detected Solid Amber Connected only PW1 or PW2 Off Both PW1 and PW2 are connected and powered Solid Green Connection Flashing Green Data Transmitting / Receiving Off No Connection Solid Green Connected Flashing
TI-PE50 / TI-PE80 / TI-PG50 / TI-PG80 / TI-PG80B PW1 PW2 Status Description Solid Green Power is Detected Off Power is Not Detected Solid Green Power is Detected Off Power is Not Detected RLY (TI-PE80, Solid Amber TI-PG80, & TI-PG80B ONLY) Off LNK POE Connected only PW1 or PW2 Both PW1 and PW2 are connected and powered Solid Green Connected Flashing Green Data Transmitting / Receiving Off No Connection Solid Amber PoE is connected Flashing Amber PoE is being detected Off No PoE
ENGLISH TI-PG160 / TI-PG162 FRANÇAIS P1 P2 DEUTSCH P3 RLAY ESPAÑOL LNK SFP (F15, F16) (TI-PG162 ONLY) PoE Status Description Solid Green Power is Detected Off Power is Not Detected Solid Green Power is Detected Off Power is Not Detected Solid Amber Power is Detected Off Power is Not Detected Solid Amber Connected only PW1 or PW2 Off Both PW1 and PW2 are connected and powered Solid Green Connection Flashing Green Data Transmitting / Receiving Off No Connection Solid Green C
Certifications This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received. Including interference that may cause undesired operation. Waste electrical an electronic products must not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or Retailer for recycling advice.