Word 1 Lo byte = ‘D
Word 2 Hi byte = ‘E
Word 2 Lo byte = ‘F
Word 3 Hi byte = ‘G
Word 3 Lo byte = ‘
Word 4 Hi byte = ‘C
Word 4 Lo byte = ‘o
Word 5 Hi byte = ‘r
Word 5 Lo byte = ‘p
Word 6 Hi byte = ‘.
Word 6 Lo byte = ‘\0
0x0020
16 words
ASCII
Product Name = “SWITCH
Word 0 Hi byte = ‘S
Word 0 Lo byte = ‘W
Word 1 Hi byte = ‘I
Word 1 Lo byte = ‘T
Word 2 Hi byte = ‘C
Word 2 Lo byte = ‘H
0x0040
7 words
Product Serial Number
Ex: Serial No=A000000000001
0x0050
12 words
ASCII
Firmware Version= 8648-999-
1.1.0.S0
Word 0 Hi byte = ‘8
Word 0 Lo byte = ‘6
Word 1 Hi byte = ‘4
Word 1 Lo byte = ‘8
Word 2 Hi byte = ‘-
Word 2 Lo byte = ‘9
Word 3 Hi byte = ‘9
Word 3 Lo byte = ‘9
Word 4 Hi byte = ‘-
Word 4 Lo byte = ‘1
Word 5 Hi byte = ‘.
Word 5 Lo byte = ‘1
Word 6 Hi byte = ‘.
Word 6 Lo byte = ‘0
Word 7 Hi byte = ‘.
Word 7 Lo byte = ‘S
Word 8 Hi byte = ‘0
Word 8 Lo byte = ‘\0
0x0060
16 words
ASCII
Firmware Release Date= Mon Sep 30
18:51:45 2013”
0x0070
3 words
HEX
Ethernet MAC Address
Ex: MAC = 00-01-02-03-04-05
Word 0 Hi byte = 0 x 00
Word 0 Lo byte = 0 x 01
Word 1 Hi byte = 0 x 02
Word 1 Lo byte = 0 x 03
Word 2 Hi byte = 0 x 04
Word 2 Lo byte = 0 x 05
0x0080
1 word
HEX
Power 1(PWR) Alarm, DIP switch 1
need ON
0x0000: no alarm
0x0001: input voltage < 44V
0x0002: input voltage > 57V
0x0003: No PWR input
0x0081
1 word
HEX
Power 2(RPS) Alarm, DIP switch 1
need ON
0x0000: no alarm
0x0001: input voltage < 44V