User's Guide
© Copyright 2018 TRENDnet. All Rights Reserved.     
TRENDnet User’s Guide 
Managed Industrial L2 Switch 
81 
configure 
no loop-detection address 
This command configures the 
destination MAC to default 
(00:0b:04:AA:AA:AB).  
interface 
loop-detection (disable | enable) 
This command disables / enables 
the loop detection on the port.  
interface 
no shutdown  
This command enables the port. It 
can unblock port blocked by loop 
detection.  
interface 
loop-detection recovery (disable 
| enable) 
This command enables / disables 
the recovery function on the port.  
interface 
loop-detection recovery time 
VALUE 
This command configures the 
recovery period time.  
configure 
interface range 
gigabitethernet1/0/ PORTLISTS 
This command enters the interface 
configure node.  
if-range 
loop-detection (disable | enable) 
This command disables / enables 
the loop detection on the ports.  
if-range 
loop-detection recovery (disable 
| enable) 
This command enables / disables 
the recovery function on the port.  
if-range 
loop-detection recovery time 
VALUE 
This command configures the 
recovery period time.  
Example: 
[DEVICE_NAME](config)#loop-detection enable 
[DEVICE_NAME](config)#interface 1/0/1 
[DEVICE_NAME](config-if)#loop-detection enable 
Web Configuration 
Advanced Settings > Loop Detection 
Parameter 
Description 
State 
Select this option to enable loop guard on the Switch.  
MAC Address 
Enter the destination MAC address the probe packets will be 
sent to. If the port receives these same packets the port will be 
shut down.  
Port 
Select a port on which to configure loop guard protection.  










