User's Guide

© Copyright 2018 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide
Managed Industrial L2 Switch
81
configure
no loop-detection address
This command configures the
destination MAC to default
(00:0b:04:AA:AA:AB).
interface
loop-detection (disable | enable)
This command disables / enables
the loop detection on the port.
interface
no shutdown
This command enables the port. It
can unblock port blocked by loop
detection.
interface
loop-detection recovery (disable
| enable)
This command enables / disables
the recovery function on the port.
interface
loop-detection recovery time
VALUE
This command configures the
recovery period time.
configure
interface range
gigabitethernet1/0/ PORTLISTS
This command enters the interface
configure node.
if-range
loop-detection (disable | enable)
This command disables / enables
the loop detection on the ports.
if-range
loop-detection recovery (disable
| enable)
This command enables / disables
the recovery function on the port.
if-range
loop-detection recovery time
VALUE
This command configures the
recovery period time.
Example:
[DEVICE_NAME](config)#loop-detection enable
[DEVICE_NAME](config)#interface 1/0/1
[DEVICE_NAME](config-if)#loop-detection enable
Web Configuration
Advanced Settings > Loop Detection
Parameter
Description
State
Select this option to enable loop guard on the Switch.
MAC Address
Enter the destination MAC address the probe packets will be
sent to. If the port receives these same packets the port will be
shut down.
Port
Select a port on which to configure loop guard protection.