Managed Industrial L2 Switch
74
Control VLAN
Configures the Control VLAN which is the ERPS control packets
domain for the ring.
Version
Configures the version for the ring.
Hold-off Timer
Configures the Hold-off time for the ring. The Valid value is
from 0 to 10000 (ms).
WTR Timer
Configures the WTR time for the ring. The Valid value is from 5
to 12 (min).
MEL
Configures the Control MEL for the ring. The Valid value is from
0 to 7. The default is 7.
Guard Timer
Configures the Guard time for the ring. The Valid value is from
10 to 2000 (ms).
Left Port
Configures the left port and its type for the ring. The valid port
type is one of Owner, Neighbor or Normal.
Right Port
Configures the right port and its type for the ring. The valid port
type is one of Owner, Neighbor or Normal.
Parameter
Description
Ring ID
The ring ID.
Ring Name
The ring name.
State
The ring state.
Revertive
The ring revertive mode.
Control VLAN
The ring Control VLAN.
Version
The protocol version on the ring.
Holdoff Timer
The Hold-off time.
WTR Timer
The WTR time.
MEL
The Control MEL.
Guard Timer
The Guard time.
Left Port
The left port.
Left Port Type
The left port type.
Right Port
The right port.
Right Port Type
The right port type.
WTB Timer
The WTB time.
Ring Status
The current ring status.
Left Port Status
The current left port status.
Right Port Status
The current right port status.