User's Guide
© Copyright 2018 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide
Managed Industrial L2 Switch
162
DIP Switch
• 1: PWR alarm relay (on or off alarm relay on power failure)
• 2: RPS alarm relay (on or off alarm relay on power failure)
Alarm Relay Output
• Relay outputs with current carrying capacity of 1A, 24V DC
• Short circuit mode when one power source is connected
• Open circuit mode when two power sources are connected
Enclosure
• IP30 rated metal enclosure
• Fanless passive cooling
• DIN-Rail mount
• Grounding Point
• ESD (Ethernet) Protection: 8KV DC
• Surge (Power) Protection: 6KV DC
MTBF
• 1,072,674 hours @ 25° C
• 177,143 hours @ 75° C
Operating Temperature
• -40° – 75° C (-40° – 167° F)
Operating Humidity
• Max. 95% non-condensing
Dimensions
• 160 x 120 x 50mm (6.3 x 4.72 x 1.97 in.)
Weight
• 884 g (1.95 lbs.)
Certifications
• CE
• FCC
• Shock (IEC 60068-2-27)
• Freefall (IEC 60068-2-32)
• Vibration (IEC 60068-2-6)