User's Guide
© Copyright 2018 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide
Managed Industrial L2 Switch
156
Terminal Block
• Redundant power inputs, alarm relay contact, 6-pin
• Wire range: 0.5 mm^2 to 2.5 mm^2
• Solid wire (AWG): 12-26
• Stranded wire (AWG): 12-26
• Wire strip length: 10-11mm
DIP Switch
Switch
Status
Function
1
OFF
Disable alarm relay for PWR power input
ON
Enable alarm relay for power failure on PWR power
input
2
OFF
Disable alarm relay for RPS power input
ON
Enable alarm relay for power failure on RPS power input
3
OFF
Storm control managed by switch configuration
ON
Enable storm control (Broadcast and DLF rate set to
300pps)
Takes precedence over storm control switch
configuration
4
OFF
802.1p QoS managed by switch configuration
ON
Enable 802.1p QoS on ports 1 and 2 (Set CoS priority to
tag 4 on ports 1 and 2)
Takes precedence over 802.1p QoS switch configuration
5
OFF
Port 9 SFP set to Gigabit speed full duplex
ON
Port 9 SFP set to 100Mbps speed full duplex
6
OFF
Port 10 SFP set to Gigabit speed full duplex
ON
Port 10 SFP set to 100Mbps speed full duplex
Alarm Relay Output
• Relay output with current carrying capacity of 1A, 24V DC
• Short circuit mode when one power source is connected
• Open circuit mode when two power sources are connected
Enclosure
• IP30 rated metal enclosure
• Fanless passive cooling
• DIN-Rail mount
• Grounding point
• ESD (Ethernet) Protection: 8KV DC
• Surge (Power) Protection: 2KV DC
MTBF
• 617,085 hours @ 25° C
• 113,378 hours @ 75° C
Operating Temperature
• -40° – 75° C (-40° – 167° F)
Operating Humidity
• Max. 95% non-condensing
Dimensions
• 160 x 120 x 50mm (6.3 x 4.72 x 1.97 in.)
Weight
• 884g (1.95 lbs.)
Certifications
• CE
• FCC
• Shock (IEC 60068-2-27)
• Freefall (IEC 60068-2-32)
• Vibration (IEC 60068-2-6)