SDS
Version: 3.1
Revision Date: 10/12/2018
000000016967
4/18
Unsuitable extinguishing
media:
Do not use water jet as an extinguisher, as this will spread the fire.
Specific hazards arising from
the chemical:
During fire, gases hazardous to health may be formed.
Special protective equipment and precautions for firefighters
Special fire fighting
procedures:
No data available.
Special protective equipment
for fire-fighters:
Self-contained breathing apparatus and full protective clothing must be
worn in case of fire.
6.
Accidental release measures
Personal precautions,
protective equipment and
emergency procedures:
Ventilate closed spaces before entering them. Evacuate area. See Section
8 of the SDS for Personal Protective Equipment. Keep upwind. Keep
unauthorized personnel away. Do not touch damaged containers or spilled
material unless wearing appropriate protective clothing.
Methods and material for
containment and cleaning
up:
Collect spillage in containers, seal securely and deliver for disposal
according to local regulations.
Notification Procedures
:
In the event of a spill or accidental release, notify relevant authorities in
accordance with all applicable regulations.
Environmental Precautions
:
Avoid release to the environment. Prevent further leakage or spillage if safe
to do so.
7.
Handling and storage
Precautions for safe handling
:
Ventilate well, avoid breathing vapors. Use approved respirator if air
contamination is above accepted level. Use mechanical ventilation in case
of handling which causes formation of dust. Do not handle until all safety
precautions have been read and understood. Obtain special instructions
before use. Use personal protective equipment as required. Do not breathe
dust/fume/gas/mist/vapors/spray. Avoid contact with eyes, skin, and
clothing. Wash hands thoroughly after handling.
Conditions for safe storage,
including any
incompatibilities:
Store locked up.
8.
Exposure controls/personal protection
Control Parameters
Occupational Exposure Limits
Chemical Identity
Type
Exposure Limit Values
Source
Calcium Carbonate
(Limestone) - Total dust.
PEL 15 mg/m3
US. OSHA Table Z-1 Limits for Air
Contaminants (29 CFR 1910.1000)
(02 2006)
Calcium Carbonate PEL 5 mg/m3
US. OSHA Table Z-1 Limits for Air