MSDS
5 of 7 pages 
Last updated 3/03/2009
Aqua Armor
 for Boat & Marine   
Material Safety Data Sheet
MSDS ID NO.: Trek7AABM  Product name: Aqua Armor for Boat & Marine  Page 5 of 7 
 Toxicity: No Data available  . 
 Irritation: No Data available   
Eye   
 Irritation: No Data available  May cause mild, short-lasting discomfort to eyes. 
Based on test data for structurally similar materials. 
CHRONIC/OTHER EFFECTS 
For the product itself: No Data available 
12. 
ECOLOGICAL INFORMATION
The information given is based on data available for the material, the components of the material, and similar materials. 
ECOTOXICITY 
Material -- Not expected to be harmful to aquatic organisms. 
Material -- Not expected to demonstrate chronic toxicity to aquatic organisms. 
PERSISTENCE AND DEGRADABILITY 
Biodegradation: 
Material – Not expected to be rapidly biodegradable. 
Hydrolysis: 
Material -- Transformation due to hydrolysis not expected to be significant. 
Photolysis: 
Material -- Transformation due to photolysis not expected to be significant. 
Atmospheric Oxidation: 
Material -- Expected to degrade in air 
.
13. 
DISPOSAL CONSIDERATIONS
Disposal recommendations based on material as supplied. Disposal must be in accordance with current applicable laws and 
regulations, and material characteristics at time of disposal. 
DISPOSAL RECOMMENDATIONS 
Do not dump into any sewers, on the ground or into any body of water. Send to a licensed and permitted waste hauler. 
REGULATORY DISPOSAL INFORMATION 
RCRA Information: Disposal of unused product may be subject to RCRA regulations (40 CFR 261). Disposal of the used 
product may also be regulated due to ignitability, corrosivity, reactivity or toxicity as determined by the Toxicity 
Characteristic Leaching Procedure (TCLP). Potential RCRA characteristics: None 
Empty Container Warning PRECAUTIONARY LABEL TEXT: Empty containers may retain residue and can be dangerous. DO NOT 
PRESSURIZE, CUT, WELD, BRAZE, SOLDER, DRILL, GRIND OR EXPOSE SUCH CONTAINERS TO HEAT, FLAME, SPARKS, STATIC 
ELECTRICITY, OR OTHER SOURCES OF IGNITION; THEY MAY EXPLODE AND CAUSE INJURY OR DEATH. Do not attempt to refill or clean 
container since residue is difficult to remove. Empty drums should be completely drained, properly bunged and promptly returned to 
a drum reconditioner. All containers should be disposed of in an environmentally safe manner and in accordance with governmental 
regulations. 