RADIANT STOVE NOTE: If a blower is being uesd, install the blower kit first and discard the power cord and strain
relief bracket from this kit. With the blower kit installed follow the steps below to electricly ground the accessories to
the appliance belly pan.
a. Disconnect the blower ground from the strain relief bracket
b. Install the AC adapter ground to the strain relief bracket where you just removed the blower ground.
c. Reinstall the blower
g
round on the extra
g
round tab attached to the remote reciever
g
round quick reliease.
1. Install the new strain-relief
bracket (stoves and inserts).
For stoves, the strain
relief bracket can be
installed anywhere on
the belly pan of the
appliance that is out of
the way of other
components (see
suggestions to the right).
Insert the stud on the
bracket through an
available hole in the
belly pan. Secure the
bracket with the included
8-32 nut.
With inserts, the bracket installs on the front of the right wall
of the gas control area below the firebox. Use the included
screw to secure the bracket. Use the included screw to
secure the bracket to one of the two existing holes in the
side of the insert (as shown to the right).