Owner's Manual
-5-
IV. f - DIVIDER BARS-DRAWERS:
Drawer models are provided with metal divider bars standard. All 27” wide 
models are supplied with 2 bars, 32” wide models are supplied with 2 narrow 
bars and 1 wide bar and 60” wide models are supplied with 2 bars and 1 hook 
divider bar, per drawer.
V. CARE AND MAINTENANCE
V. a - CLEANING THE EXTERIOR: 
Exterior stainless steel should be cleaned with warm water, mild soap and a soft 
cloth. Apply with a dampened cloth and wipe in the direction of the metal grain.  
Avoid the use of strong detergents and gritty, abrasive cleaners as they may tend 
to mar and scratch the surface. Do NOT use cleaners containing chlorine, this 
may promote corrosion of the stainless steel.
V. b - CLEANING THE INTERIOR:
For cleaning the interior, the use of baking soda as described in section V. a is 
recommended. Use on breaker strips as well as door and drawer gaskets. 
All door models interior fittings are removable without tools to facilitate cleaning.
Depending on the level of cleaning, drawer models interior fittings may require 
a tool to facilitate cleaning. The drawer frame may be removed without tools by  
simply pulling out and upward. For deeper cleaning the back panel shown in the 
bubble drawing will require a Phillips screwdriver to be removed.
For additional deeper cleaning you may also remove the air duct by removing the 
thumb screws and rotating them in counter clockwise motion.
IV. c - DEFROST CONTROL: (continued)
This control can be adjusted to set when the next defrost cycle will 
start. To adjust the defrost time control, use a coin on the outside slot 
in the rim of the timer and turn clockwise until the compressor turns 
off. Continue turning coin clockwise until the compressor restarts.  
The next defrost cycle will start in about 5 hours 40 minutes. On all 
models ULT27, ULT48 and ULT60, the defrost time control is located 
on the front side of the evaporator housing, behind the temperature 
control adjustment screw. On earlier models ULT48 and ULT60, the 
defrost time control was accessed through a small round opening on 
the outside rear of the unit.
ULT32 freezer model requires no adjustment. The defrost occurs every 
4 hours. It is time initiated and temperature terminated with a time 
safety backup.
IV. d - REFRIGERATING PRODUCT:
A thermometer is provided inside all UHT, ULT, UPT & UST models. Al-
low the cabinet to reach normal operating temperature before loading.
UHT, ULT, UPT & UST Series will satisfactorily refrigerate an assorted 
load of food items. Allow space between articles to permit free air 
circulation. Do not overload at any one time with warm food products 
and expect immediate results. A certain amount of time is required to 
remove heat from items before operating temperatures can be attained.  
The system is designed for storage of refrigerated or frozen product.
Opening the door or drawer will increase the temperature in the cabinet 
and will require a certain amount of time to recover. Also after peak 
service periods or after warm product is loaded the refrigerator will 
require a certain amount of time for the temperature to return to the 
normal operating range.
IV. e - PANS & DIVIDER BARS-TOP RAIL:
Sandwich Prep models are provided with 1/6 size plastic pans and 
metal divider bars. When 18 one sixth size pans are ordered, four 
standard and one wide pan divider/supports are provided to achieve 
appropriate pan separation. When 24 one-sixth size pans re ordered, 
six standard and one wide pan divider bars are provided to achieve 
appropriate pan separation. All other arrangements use all standard 
width pan divider bars.
IV.OPERATION (continued)
IV.OPERATION (continued)
SLIDING RAIL
DRAWER
SLIDING RAIL
CABINET 
ROLLERS