Install Instructions

©2017 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • (336) 629-4651
MNL-TZ 24
A THERMACO® Technology
Trapzilla
®
Grease Interceptor
Installation and Operations Manual
TZ-160, TZ-400, TZ-600 Models
AFE
MNL-TZ 23
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SO
LE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739
Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1
°
CHECKED
SIZE
REV. NO.
DWG NO.
PART NO.
C
SCALE
RELEASE DATE
SHEET OF
ENGINEERING
DRAWN
DATE
THIRD ANGLE PROJECTION
42.00 in
[106.7 cm]
42.00 in
[106.7 cm]
32.00 in
[81.3 cm]
Typical
Support
Rod
Spacing
52.51 in
[133.4 cm]
5.00 in
[12.7 cm]
5.00 in
[12.7 cm]
40.01 in
[101.6 cm]
Top View
Outlet End View Side View
38.00 in
[96.5 cm]
TYP
42.50 in
[108.0 cm]
13.00 in
[33.0 cm]
Outlet
12.50 in
[31.8 cm]
Inlet
2 Inch
NPT
Vent
4.50 in
[11.4 cm]
4" Nom
Inlet &
Outlet
Thermaco, Inc. supplies the frame and support stand with the hanging assembly. This kit
needs to be installed by a licensed contractor. The contractor is responsible for determining
weight loads, preparation of the oor for installation and any construction necessary for
installation of the suspension kit.
6.0 Hanging Installation
Using the Hanging Assembly option, a Trapzilla unit may be suspended from a ceiling below the oor
of a kitchen or other room.
Trapzilla unit must be
purchased separately.
*SSOP-400/600
Support Stand
Included with
HA-400/600
**SSA-160
Support Stand
Included with
HA-160
7.0 Measuring Grease/Solids Levels
Due to its unique design, Trapzilla is capable of retaining high quantities of grease in a compact footprint.
Therefore, unlike traditional interceptors, Trapzilla can hold an extraordinarily high percentage of its
volume in grease without losing separation efciency. To determine the current levels of grease/solids
in your Trapzilla grease interceptor, follow the instructions below.
1. Remove four nuts/washers securing the Solid Top Cover. Note the size of the unit which is marked
on the cover by a metal plate.
2. Place a grease/sludge dipstick into the center of the Trapzilla, making sure that it goes through
the hole in the horizontal bafe.
3. Once the dipstick has found its natural resting place at the lowest point in the conical shaped
bottom, take the measurement.
4. Remove dipstick and compare grease/sludge levels to the corresponding unit in the charts below.
Grease Solids
Total
Capacity
(depth):
Ready to
pump at
(depth):
Total
Capacity
(height):
Ready to
pump at
(height):
TZ-600 17” 13.75” 14” 12”
TZ-400 9.375” 7.5” 14” 12”
TZ-160 13” 10.5” 10” 8”
Take solids/sludge measurement from
bottom of unit upward and compare to
chart above.
Take grease measurement from top of
liquid level downward and compare to
chart above.
Note: Drawing for reference only. Equipment must be installed in compli-
ance with all applicable laws, regulations and codes, including plumbing