7.2 Pumping/Servicing Unit
Periodically, the Trapzilla
®
Solids Separator will need to be
serviced which involves pumping out the accumulated grease
& solids. Each lid has four brass nuts securing the lid. Fully
remove the 22” lid to access the solids. Begin by taking the
solids from the top of the tank. Be sure to lower the hose all
the way to the bottom of the Trapzilla unit so that solids may be
entirely removed.
The Grease or Solids building up inside the Trapzilla unit may
be gauged using a Sludge Judge or similar device.
Note:
1) Do NOT use mechanical crust breaking devices to break down any mat that has formed inside
the Trapzilla Solids Separator.
2) Remove the four brass nuts from the bolts and fully remove the lid to pump out.
3) It is not necessary to remove adapter lid (ring) to pump out the Trapzilla Solids Separator.
Hose to pump truck
TSS-95 with standard adapter
ring (cover removed)
Drop hose into Solids Separator, pumping
out all liquids and solids in the unit.
It may be necessary to use water hose to
rinse out chamber.
8.0 Limited Warranty & Remedy
Thermaco, Inc. warrants to the original user that the equipment manufactured by Thermaco and delivered
with this warranty (the “Product”) shall be free from material defects in workmanship and materials during
the lifetime of the plumbing system in which the Product is initially installed.
Any claim under this warranty must be made in writing to Thermaco at 646 Greensboro Street, Asheboro,
NC 27203 promptly after discovery of the defect and the Product must be delivered, prepaid, to
Thermaco, together with proof of purchase and a return authorization number issued by Thermaco. If
Thermaco determines that the Product is defective, Thermaco’s sole obligation, and the purchaser’s
sole and exclusive remedy, is the repair or replacement, at Thermaco’s option, of the defective Product.
This warranty shall not cover any defect or damage resulting directly or indirectly from: (i) failure to
properly install, operate or maintain the Product in accordance with Thermaco’s instructions, including,
without limitation, use in excess of rated ow, installation deeper than manufacturer’s recommendation
or in conjunction with unapproved components, use to remove emulsied fats and oils or use that fails
to comply with applicable laws, regulations or codes; (ii) damage in transit, handling or installation; (iii)
modications, adjustments, or alterations of the Product; (iv) disassembly of components other than as
required for prescribed maintenance; or (v) any other causes not arising out of defects in workmanship
or materials. Thermaco shall not be responsible for damage to Products resulting from ultraviolet light
exposure, vault ooding, sewer line back-up, pumping or lift station failure, ambient water ow, freezing, or
other sources of water damage. Costs for any service, adjustment, removal, repair, packing, or otherwise
incurred with respect to the Product prior to submission for warranty are the responsibility of purchaser.
No distributor, sales representative or other person is authorized to make any warranty statements
on behalf of Thermaco regarding Products other than as provided herein. This statement of warranty
supersedes any quote, brochure, or other statement or document with respect to warranty of Thermaco
products.
EXCEPT AS EXPRESSLY SET FORTH ABOVE, THERMACO MAKES NO REPRESENTATIONS,
WARRANTIES OR GUARANTEES, EITHER EXPRESSED OR IMPLIED, INCLUDING, WITHOUT
LIMITATION, AS TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHETHER
OR NOT THERMACO HAD KNOWLEDGE OF PURCHASER’S PARTICULAR REQUIREMENTS OR
NEEDS, OR WITH RESPECT TO ODOR GENERATION OR OTHER INCIDENTALS RELATING TO
USE OF THE PRODUCT.
The sole and exclusive remedy with respect to this warranty or any other claim relating to defects or any
other condition or use of Products, however caused, and whether such claim is based upon warranty,
contract, tort, strict liability or any other theory, is LIMITED to the repair or replacement of the Product,
excluding any cost to remove or install the Product or, at Thermaco’s option, repayment of the purchase
price. IN NO EVENT SHALL THERMACO BE LIABLE, WHETHER IN CONTRACT, WARRANTY,
TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY, INDEMNITY OR ANY OTHER LEGAL
THEORY, FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. UNDER NO CIRCUMSTANCES
WILL THE AGGREGATE LIABILITY OF THERMACO FOR ANY CAUSE OF ACTION RELATED
TO THE PRODUCT COVERED HEREBY EXCEED THE NET PURCHASE PRICE RECEIVED BY
THERMACO FOR THE PRODUCT.