Thermaco, Inc. supplies the frame and SSOP-70/95 with the HA-70/95. This kit needs to be
installed by a licensed contractor. The contractor is responsible for determining weight loads,
preparation of the oor for installation and any construction necessary for installation of the
suspension kit.
6.0 Hanging Installation
Using the HA-70/95 model, a Trapzilla unit may be suspended from a ceiling below the oor of a kitchen
or other room.
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SO
LE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739
Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1
°
CHECKED
SIZE
REV. NO.
DWG NO.
PART NO.
C
SCALE
RELEASE DATE
SHEET OF
ENGINEERING
DRAWN
DATE
THIRD ANGLE PROJ ECTION
42.00 in
[106.7 cm]
42.00 in
[106.7 cm]
32.00 in
[81.3 cm]
Typical
Support
Rod
Spacing
52.51 in
[133.4 cm]
5.00 in
[12.7 cm]
5.00 in
[12.7 cm]
40.01 in
[101.6 cm]
Top View
Outlet End View Side View
38.00 in
[96.5 cm]
TYP
42.50 in
[108.0 cm]
13.00 in
[33.0 cm]
Outlet
12.50 in
[31.8 cm]
Inlet
2 Inch
NPT
Vent
4.50 in
[11.4 cm]
4" Nom
Inlet &
Outlet
Trapzilla Solids
Separator must be
purchased separately.
Support Stand
Included with
HA-70/95
7.0 Unit Maintenance
7.1 Measuring Solids Levels
Trapzilla Solids Separators are capable of retaining high quantities of solids in a compact footprint. To
determine the current levels of solids in your Trapzilla Solids Separator, follow the instructions below.
1. Remove four nuts/washers securing the Solid Top Cover. Note the size of the unit which is marked
on the cover by a metal plate.
2. Place a grease/sludge dipstick into the center of the unit, making sure that it goes all the way to
the bottom.
3. Once the dipstick has found its natural resting place at the lowest point in the conical shaped
bottom, take the measurement.
4. Remove dipstick and compare sludge levels to the corresponding unit in the charts below.
Solids
Total
Capacity:
Ready to
pump at:
TSS-95 32” 27”
TSS-70 24” 21”
Dipstick Pro measuring device
TSS-95 with standard adapter
ring (cover removed)
Take measurement from
bottom of unit upward and
compare to chart above.
Note: Drawing for reference only. Equipment must be installed in
compliance with all applicable laws, regulations and codes, including
plumbing codes. Installation should be performed by a qualied