Install Guide
25
Unacceptable Connection Types
a) T-Taps
b) Spade Terminals
c) Marrettes
d) Blade Connectors
e) Standard Butt Splices
5) WIRE TYPES
The following are the minimum specifications for hook-up
wire that should be used during the installation process:
a) Ranger Power and Ground
300V, 105°C PVC, 18AWG stranded
b) Ignition
300V, 105°C PVC, 22AWG stranded
c) Odometer Interface
300V, 105°C PVC, 22AWG stranded
d) Ranger Inputs (i.e. Emergency Input, etc.)
300V, 105°C PVC, 22AWG stranded
6) ELECTRICAL MEASUREMENTS
Always ensure that there is adequate voltage at the point
where Ranger is being powered. Compare this voltage to the
voltage at the battery. The two voltages should be almost the
same or a different power point should be chosen closer to
the battery.