Operation Manual
VLAN Commands
Mobility System Software Command Reference Guide
Version 7.3
6 – 82
Access
All.
History
Introduced in MSS Version 1.0.
Examples
The following command displays information for VLAN burgundy:
MX# show vlan config burgundy
Admin VLAN Tunl Port
VLAN Name Status State Affin Port Tag State
---- ---------------- ------ ----- ----- ---------------- ----- -----
2 burgundy Up Up 5
2 none Up
3 none Up
4 none Up
6 none Up
11 none Up
t:10.10.40.4 none Up
Table 6– 17 describes the fields in this display.
See Also
● clear vlan on page 6-70
● set vlan name on page 6-73
● set vlan port on page 6-74
● set vlan tunnel-affinity on page 6-75
Table 6– 17. Output for show vlan config
Field Description
VLAN VLAN number.
Name VLAN name.
Admin Status Administrative status of the VLAN:
❑ Down—The VLAN is disabled.
❑ Up—The VLAN is enabled.
VLAN State Link status of the VLAN:
❑ Down—The VLAN is not connected.
❑ Up—The VLAN is connected.
Tunl Affin Tunnel affinity value assigned to the VLAN.
Port Member port of the VLAN. The port can be a physical port or a virtual port.
❑ Physical ports are 10/100 Ethernet or gigabit Ethernet ports on the switch,
and are listed by port number.
❑ Virtual ports are tunnels to other switches in a mobility domain, and are
listed as follows: t:ip-addr, where ip-addr is the system IP address of the
MX switch at the other end of the tunnel.
Note: This field can include MP access ports and wired authentication
ports, because MSS dynamically adds these ports to a VLAN when
handling user traffic for the VLAN.
Tag Tag value assigned to the port.
Port State Link state of the port:
❑ Down—The port is not connected.
❑ Up—The port is connected.