Operation Manual

System Services Commands
System Services Commands
4 – 41
See Also
clear system on page 4-21
set system contact on page 4-30
set system countrycode on page 4-30
set system idle-timeout on page 4-34
set system ip-address on page 4-35
Table 4– 2. show system Output
Field Description
Product Name MX model number.
System Name System name (factory default, or optionally configured with set system name).
System
Countrycode
Country-specific 802.11 code required for MP operation (configured with set system
countrycode).
System Location Record of MX physical location (optionally configured with set system location).
System Contact Contact information about the system administrator or another person to contact
about the system (optionally configured with set system contact).
System IP Common interface, source, and default IP address for the MX, in dotted decimal
notation (configured with set system ip-address).
System Secret A password configured for MX-MX security.
System idle timeout Number of seconds MSS allows a CLI management session (console, Telnet, or SSH)
to remain idle before terminating the session. (The system idle timeout can be
configured using the set system idle-timeout command.)
System MAC MX media access control (MAC) machine address set at the factory, in 6-byte
hexadecimal format.
Boot Time Date and time of the last system reboot.
Uptime Number of days, hours, minutes, and seconds that the MX has been operating since
its last restart.
Fan status Operating status of the three MX cooling fans:
OK—Fan is operating.
Failed—Fan is not operating. MSS sends an alert to the system log every 5 minutes until
this condition is corrected.
Fan 1 is located nearest the front of the chassis, and fan 3 is located nearest the back.
Temperature Status of temperature sensors at three locations in the MX switch:
ok—Temperature is within the acceptable range of 0° C to 50° C (32° F to 122° F).
Alarm—Temperature is above or below the acceptable range. MSS sends an alert to the
system log every 5 minutes until this condition is corrected.
PSU Status Status of the lower and upper power supply units:
missing—Power supply is not installed or is inoperable.
DC ok—Power supply is producing DC power.
DC output failure—Power supply is not producing DC power. MSS sends an alert to the
system log every 5 minutes until this condition is corrected.
AC ok—Power supply is receiving AC power.
AC not present—Power supply is not receiving AC power.
Memory Current size (in megabytes) of nonvolatile memory (NVRAM) and synchronous
dynamic RAM (SDRAM), plus the percentage of total memory space in use, in the
following format:
NVRAM size /SDRAM size (percent of total)
Total PoE Draw (W) Total power that the MX is currently supplying to directly connected MPs, in watts.