Quick Start Manual
Table Of Contents
Quick Start
Quick Start For Bridging (PxP)
Figure 32
Customer Unit TR-2015/2018/1000/2000
1. Plug the Cat 5 cable coming out of the TR-2015/2018/2000 (the MDI port on the TR–1000) into the port marked CPE on the
DC injector. Plug another cable into the PC port on the DC injector and into an Ethernet adaptor for a single PC or an uplink
port on a hub for multiple computers. Plug the DC power supply into the DC Injector.
2. Install the Access Point Utility. Execute the utility and double click on the icon of the TR-2015/2018/1000/2000. Enter the
Password. The default password is “default”.
3. From the Configuration Tab select the General tab. Name the Access Point so you can easily identify the unit.
4. Click the IEEE802.11 tab and use the drop down menu to set the Radio Mode Inter-Building with Repeating (PxP).
Figure 33
5. Set the channel for your TR-2015/2018/1000/2000.
Ensure both TR-2015/2018/1000/2000’s are set to the same channel.
6. Hit apply. Click OK for reset.
7. Repeat for the other TR-2015/2018/1000/2000.
8. To check signal strength start a telnet session by going to the Start Menu and select Run. Type in “telnet” and the IP of the
unit. Enter password. The default password is “default”. Type “stat” and hit enter. Signal Strength is displayed across the top.
To manage the TR-2015/2018/1000/2000 from inside your network use the gateway’s address to telnet or when using your
browser. To remotely manage the TR-2015/2018/1000/2000 (from an outside location) use the IP address of the TR-
2015/2018/1000/2000.