User's Manual
Warning Alarm
The warning sound will be emitted from the monitor unit in the following cases.
4.2
Note : You can press any key of monitor stop the alarm.
Status Bar
The status bar will be displayed on the top of the screen. See Fig. 27.
1. Camera number indicator
2. Signal strength indicator
3. Temperature indicator (Camera side)
4. Battery status / Charging indicator
Status Information
4
4.1
Flip Function
In this submenu you can flip the video horizontally when mounting the camera
on the ceiling. See Fig. 25.
3.12
Restore Default
In this submenu you can reset the system to default. Press to make sure.
See Fig. 26.
3.13
7
Status Indication Action
Out of range
Lost connection
Continuous beeps
for one minute
Move the monitor closer
to the camera. Check the
power of camera.
Temperature alarm 2 consecutive beeps and
temperature indicator
on the screen blinking
Check the temperature of
camera side.
Disable temperature alert
(See Setup 3.4)
VOX alarm 3 consecutive beeps Disable VOX function
(See Setup 3.5)
Low battery
2 consecutive beeps and
on the screen
blinking
Connect the monitor unit
to the AC adapter.
(See Setup 2.1)