version:1.0 User Manual Blood Pressure Monitor TMB-2084-T Arm Type Guangdong Transtek Medical Electronics Co., Ltd. Zone B, No.105 ,Dongli Road, Torch Development District, Zhongshan,528437,Guangdong,China EC REP Thank you very much for selecting TRANSTEK Blood Pressure Monitor TMB-2084-T. Please read the user manual carefully and throughtly so as to ensure the safe usage of this product, keep the manual well for further reference in case you have problems.
Table of Contents CATALOGUE INTRODUCTION..................................................................................................................2 General Description Indications for Use Contraindications Measurement Principle Safety Information LCD Display Signal Monitor Components List BEFORE YOU START..........................................................................................................
INTRODUCTION General Description Thank you for selecting TRANSTEK arm type blood pressure monitor (TMB-2084-T). The monitor features blood pressure measurement, pulse rate measurement and the result storage. The design provides you with two years of reliable service. Readings taken by the TMB-2084-T are equivalent to those obtained by a trained observer using the cuff and stethoscope auscultation method.
INTRODUCTION CAUTION 7KLV GHYLFH LV LQWHQGHG IRU DGXOW XVH LQ KRPHV RQO\ 7KH GHYLFH LV QRW VXLWDEOH IRU XVH RQ QHRQDWDO SDWLHQWV SUHJQDQW ZRPHQ SDWLHQWV ZLWK implanted, electronical devices, patients with pre-eclampsia, premature ventricular beats, atrial fibrillation, peripheral, arterial disease and patients undergoing intravascular therapy or arterio-venous shunt or people who received a mastectomy. Please consult your doctor prior to using the unit if you suffer from illnesses.
INTRODUCTION CAUTION 'R QRW ZDVK WKH FXII LQ D ZDVKLQJ PDFKLQH RU GLVKZDVKHU 7KH VHUYLFH OLIH RI WKH FXII PD\ YDU\ E\ WKH IUHTXHQF\ RI ZDVKLQJ VNLQ FRQGLWLRQ DQG storage state. The typical service life is 10000 times. ,W LV UHFRPPHQGHG WKDW WKH SHUIRUPDQFH VKRXOG EH FKHFNHG HYHU\ \HDUV DQG DIWHU maintenance and repair, by retesting at least the requirements in limits of the error of the FXII SUHVVXUH LQGLFDWLRQ DQG DLU OHDNDJH WHVWLQJ DW OHDVW DW PP+J DQG PP+J 3OHDVH GLVSRVH RI $&&(6625,
BEFORE YOU START INTRODUCTION The Choice of Power Supply Monitor Components 1.Battery powered mode: 6VDC 4×AAA batteries Component list of pressure measuring system CUFF AIR HOSE 1 Cuff 2 Air Hose 3 PCBA 4 Pump 5 Valve AIR CONNECTOR PLUG DC POWER SOCKET SET BUTTON LCD DISPLAY START/STOP BUTTON MEM BUTTON BATTERY COMPARTMENT 5V 1A (Please only use the recommended AC DGDSWRU PRGHO Please unplug the adaptor to depart from the using utility power.
BEFORE YOU START BEFORE YOU START Setting Date, Time and Measurement Unit It is important to set the clock before using your blood pressure monitor, so that a time stamp can be assigned to each record that is stored in the memory. (The setting range of the year :2020—2099) 3.When you get the right year, press “START/STOP” to set down and turn to next step. 1.When the monitor is off, long press “SET”button,it will display [YEAR]. Each press “SET” button will increase the number. 4.
BEFORE YOU START BEFORE YOU START 5.Repeat steps 2 and 3 to set the [HOUR] and [MINUTE]. 7.After the unit is set,the LCD will display “dOnE” and then it will turn off. Setting the voice switch 1.When the monitor is off,press both “STRAT/STOP” and “SET” button, it will enter voice setting mode. The vocie switch will blink, press “MEM” button to decrease the volume, press “SET” button to increase the volume, the press “START/STOP” button to confirm then the monitor will turn off. 6.
BEFORE YOU START BEFORE YOU START Setting the clock 1. When the monitor is off, long press both “SET” and “MEM” button, it will enter clock setting mode. Press “MEM” or “SET” button to choose turn off or turn on. Press“START/STOP” button to confirm. Setting the User ID 1.When the monitor is off, hold press “SET” button and then the user ID will shows. Press “MEM” or “SET”button to switch the user ID between user 1 and user 2 mode. 2.
BEFORE YOU START Install the App and Pair-Up Download the Transtek Health app from APP Store or Google Play. Install the APP, and register an account. BEFORE YOU START Search your test information After binding the app, back to the beginning page and click “Blood Pressure” to search your test information.
MEASUREMENT RF Frequency Range: 2402 MHz to 2480 MHz Output Power Range: < dBm Supply Voltage: 1.8-3.6 V Transmitting Distance: 10 meters Tie the cuff 1. Remove all jewelry, such as watches and bracelets from your left arm. Note: If your doctor has diagnosed you with poor circulation in your left arm, use your right arm. 2. Roll or push up your sleeve to expose the skin. Make sure your sleeve is not too tight. List of compatible devices: For iOS devices: The operating system must be iOS 11.0 or more.
DATA MANAGEMENT MEASUREMENT Start the Measurement Before you start the measurement,Download the Transtek Health app from APP Store or Google Play,and turn on the Bluetooth. Install the APP, and register an account. Then set your personal information (Gender, Birthday, Height, Weight, Name and so on). 1.Please switch the User button to select the user between User 1 and User 2.
DATA MANAGEMENT DATA MANAGEMENT Recall the Records 1. When the monitor is off, please hold press the “MEM”,it will display the latest record first when the records are less than three groups. When there are three or more than three groups ,it will display the average value of the latest three records first. Delete the Records If you did not get the correct measurement, you can delete all results for the selected user by following steps below. 1.
INFORMATION FOR USER INFORMATION FOR USER Maintenance Tips for Measurement Measurements may be inaccurate if taken in the following circumstances. Within 1 hour after dinner or drinking Within 20 minutes after taking a bath Immediate measurement after tea, coffee, smoking In order to get the best performance, please follow the instructions below. Put in a dry place and avoid the sunshine Avoid touching water, clean it with a dry cloth in case.
ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE What are systolic pressure and diastolic pressure? When ventricles contract and pump blood out of the heart, the blood pressure reaches its maximum value in the cycle, which is called systolic pressure. When the ventricles relax, the blood pressure reaches its minimum value in the cycle, which is called diastolic pressure.
SPECIFICATIONS TROUBLESHOOTING This section includes a list of error messages and frequently asked questions for problems you may encounter with your blood pressure monitor. If the products not operating as you think it should, check here before arranging for servicing. PROBLEM SYMPTOM No power Low batteries light up. Display is dim or show E02 shows E03 shows E04 shows H bAt shows E+ ,shows on the display. EEx,shows on the display.
COMPLIED STANDARDS LIST AUTHORIZED COMPONENT Authorized Component FCC Statement 1 please use the TRANSTEK FCC ID: OU9TMB2080-B This device complies with Part 15 of the FCC Rules. Operation issubject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
EMC GUIDANCE EMC GUIDANCE Complied Standards List Risk management EN ISO 14971:2012 / ISO 14971:2007 Medical devices Application of risk management to medical devices Labeling EN ISO 15223-1:2016 / ISO 15223-1:2016 Medical devices. Symbols to be used with medical device labels, labelling and information to be supplied.
EMC GUIDANCE Table 3 Table 2 Guidance and manufacturer’s declaration – electromagnetic Immunity Immunity Test Electrostatic discharge (6' IEC 61000-4-2 Electrical fast transient/burst IEC 61000-4-4 IEC 60601-1-2 Test level Compliance level ±8 kV contact ±2 kV, ±4kV, ±8 kV, ±15 kV air ±8 kV contact ±2 kV for power supply lines ±1 kV signal input/output 100 kHz repetition frequency ±2 kV, ±4kV, ±8 kV, ±15 kV air ±2 kV for power supply lines ±1 kV signal input/output 100 kHz repetition frequency Su