Version: 1.0 User Manual Arm Blood Pressure Monitor Model: TMB-1491-BHJ Arm Type Guangdong Transtek Medical Electronics Co., Ltd. Zone B, No.105, Dongli Road, Torch Development District, Zhongshan, 528437, Guangdong, China Thank you for selec�ng Transtek Blood Pressure Monitor. Please read the user manual carefully and thoroughly so as to ensure the safe usage of this product. Keep this manual for further reference in case any issues arise.
CATALOGUE Table of Contents INTRODUCTION.......................................................................................................................................2 General Descrip�on Indica�ons for Use Contraindica�ons Measurement Principle Safety Informa�on LCD Display Signal Monitor Components List BEFORE YOU START..................................................................................................................................
INTRODUCTION General Description This product features blood pressure measurement, pulse rate measurement and the result storage. The design provides you with two years of reliable service. Readings taken by this blood pressure monitor TMB-1491-BHJ is equivalent to those obtained by a trained observer using the cuff and stethoscope ausculta�on method. This manual contains important safety and care informa�on, and provides step by step instruc�ons for using this blood pressure monitor.
INTRODUCTION CAUTION * This device is intended for adult use in homes only. * The device is not suitable for use on neonatal patients, pregnant women, patients with implanted, electronical devices, patients with pre-eclampsia, premature ventricular beats, atrial fibrillation, peripheral, arterial disease and patients undergoing intravascular therapy or arterio-venous shunt or people who received a mastectomy. Please consult your doctor prior to using the unit if you suffer from illnesses.
INTRODUCTION CAUTION * The service life of the cuff may vary by the frequency of washing, skin condition, and storage state. The typical service life is 10000 times. * It is recommended that the performance should be checked every 2 years and after maintenance and repair, by retesting at least the requirements in limits of the error of the cuff pressure indication and air leakage (testing at least at 50mmHg and 200mmHg).
INTRODUCTION BEFORE YOU START Monitor Components CUFF AIR HOSE Component list of pressure measuring system 1 Cuff 2 Air pipe 3 PCBA 4 Pump 5 Valve The Choice of Power Supply 1. Ba�ery powered mode: 6V DC 4× AAA ba�eries 2. AC adapter powered mode: 6V 1A (Please only use the recommended AC adapter) Please unplug the adapter to depart from the using u�lity power, when you finish the measurement.
BEFORE YOU START Setting Date and Time BEFORE YOU START 4. Repeat steps 2 and 3 to set the [MONTH] and [DAY]. It is important to set the Date and Time before using your blood pressure monitor, so that a �me stamp can be assigned to each record that is stored in the memory. (The se�ng range of the year: 2017—2057, Time format: 12/24H) 1. When the monitor is off, hold press “SET” bu�on, the display will show a blinking number represen�ng the [YEAR].
BEFORE YOU START 6. Repeat steps 2 and 3 to set the [UNIT]. BEFORE YOU START Select the User ID 1. When the monitor is off, hold press “MEM” bu�on, the user ID will show. Then press “MEM” bu�on to switch the user ID between user 1, user 2 and USER G (guest). 7. A�er the UNIT is set, the LCD will display “donE” first, then display all the se�ngs you have done and then it will turn off. 2. Press “SET” bu�on to ensure your choice, it will show User ID and “donE” and then turn off.
BEFORE YOU START BEFORE YOU START Pair-up the Blood Pressure Monitor with Your Device 1.Download the MedM Health app from APP Store or Google Play. Install the APP, and register an account. t urn on Bluetooth and the app. Make sure both are ON when pair-up is proceeding. 2.When the monitor is OFF, press and hold the START/STOP bu�on to start pair-up. The symbol and will be shown on the LCD alterna�vely, indica�ng pair-up is proceeding. 3.
MEASUREMENT MEASUREMENT Start the Measurement Tie the cuff Before you start the measurement, Download the MedM Health app from APP Store or Google Play, and turn on the Bluetooth. Install the APP, and register an account. Then set your personal informa�on (Gender, Birthday, Height, Weight, Name and so on). 1. Remove all jewelry, such as watches and bracelets from your le� arm. Note: If your doctor has diagnosed you with poor circula�on in your le� arm, use your right arm. 2.
DATA MANAGEMENT MEASUREMENT If the data transmission fails, the Bluetooth symbol blinks all the �me un�l it turns off. Recall the Records 1. When the monitor is off, press “MEM” bu�on, it will display the latest record first when the records are less than three groups. When there are three or more than three groups, it will display the average value of the latest three records first. If the data transmission succeeds, the Bluetooth symbol will light up for several seconds then the device will turn off.
DATA MANAGEMENT Delete the Records If you did not get the correct measurement, you can delete all results for the selected user by following steps. (Take User 1 for example.) INFORMATION FOR USER Tips for Measurement Measurements may be inaccurate if taken in the following circumstances. 1. Hold press “MEM” bu�on, when the monitor is in the memory recall mode, the display will show “dEL ALL” + User ID.
ABOUT BLOOD PRESSURE INFORMATION FOR USER Maintenance What are systolic pressure and diastolic pressure? In order to get the best performance, please follow the instruc�ons below. When ventricles contract and pump blood out of the heart, the blood pressure reaches its maximum value in the cycle, which is called systolic pressure. When the ventricles relax, the blood pressure reaches its minimum value in the cycle, which is called diastolic pressure.
ABOUT BLOOD PRESSURE TROUBLE SHOOTING Why does my blood pressure fluctuate throughout the day? Why do I get different blood pressure at home compared to the hospital? The blood pressure is different even throughout the day due to weather, emo�on, exercise etc. Also, there is the “white coat” effect, which means blood pressure usually increases in clinical se�ngs. PROBLEM No power Low batteries If the cuff is �ed properly. If the cuff is too �ght or too loose. If the cuff is �ed on the upper arm.
AUTHORIZED COMPONENT SPECIFICATIONS Power supply Display mode Measurement mode Measurement range Accuracy Normal working condition Ba�ery powered mode: 6V DC 4× AAA ba�eries AC adapter powered mode: 6V 1A (Please only use the recommended AC adapter). Digital LCD V.A. 60 mm × 40.5 mm Oscillographic tes�ng mode Rated cuff pressure: 0 mmHg ~ 299 mmHg (0 kPa ~ 39.9 kPa) Measurement pressure: SYS: 60 mmHg ~ 230 mmHg (8.0 kPa ~ 30.7 kPa) DIA: 40 mmHg ~ 130 mmHg (5.3 kPa ~ 17.
COMPLIED STANDARDS LIST FCC STATEMENT FCC Statement FCC ID:OU9TMB1491BJ This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
EMC GUIDANCE EMC GUIDANCE EMC Guidance Table 2 The ME EQUIPMENT or ME SYSTEM is suitable for home healthcare environments. Warning: Don’t be near the active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high. Warning: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation.
EMC GUIDANCE Table 3 Guidance and manufacturer’s declaration - electromagnetic Immunity Radiated RF Test Band Service IEC61000-4-3 Frequency (MHz) (MHz) (Test specifications 380-390 TETRA 385 for ENCLOSURE 400 PORT IMMUNITY to 450 430-470 GMRS 460, RF wireless FRS 460 communications 710 704-787 LTE Band equipment) 13, 745 17 780 810 800-960 870 930 1720 1845 17001990 1970 Modulation Distance IMMUNITY TEST (W) (m) LEVEL (V/m) Pulse modulation b) 18 Hz 1.8 0.