44
Save Configuration
Save the industrial switch configuration to the flash memory. Power off the industrial switch without
the saving, all changed configuration will lost.
•
Click the
Save Flash
button the save the configuration
Save Configuration Interface
Rate Control
Set up every port’s bandwidth rate and packet limitation type
• Limit Packet type: Select the packet type that wants to filter. The packet types have all
type packet, broadcast/multicast/unknown unicast packet, broadcast/multicast packet, and
broadcast packet only. The broadcast/multicast/unknown unicast packet,
broadcast/multicast packet, and broadcast packet only are only for ingress packet. The
egress rate only supports all type packets
• Band Width: The port1 ~ port 8, supports port ingress and egress rate control. For
example, assume port 1 is 10Mbps, users can set it’s effective egress rate as 1Mbps,
ingress rate is 500Kbps. The switch performs the ingress rate by packet counter to meet
the specified rate
• Ingress: Select the port effective ingress rate. The valid range options are 128kbps,
256Kbps, 512Kbps, 1MB, 2MB, 4MB, and 8MB. The default value is “disable”
• Egress for all: Select the port effective egress rate. The valid range options are 128kbps,
256Kbps, 512Kbps, 1MB, 2MB, 4MB, and 8MB. The default value is “disable”
•
And then, click
Apply
button to apply the configuration