Switch User Manual

28
Event Configuration
The selected events that occur will send out the alert to the assigned SMTP server. Also, user can
select port events for alerting.
System event selection: 4 selections – Device cold start, Power status, SNMP Authentication
Failure, and X-Ring topology changes. Mark the checkbox to select the event. When selected
events occur, the system will sent out the alerting
Device cold start: When the device executes cold start action, the system will send out
the alert to the dedicate SMTP server
Power status: When the device power status has changed, the system will send out the
alert to the dedicate SMTP server
SMNP Authentication Failure: When the SNMP authentication fail, the system will
send out the alert to the dedicate SMTP server
X-Ring topology change: When the X-Ring topology has changed, the system will
send out the alert to dedicate SMTP server
Port event selection: Select the per port events. Per port has 3 selections – Link UP, Link
Down, and Link UP & Link Down. Disable means no event is selected
Link UP: The system will send out an alert when port connection is up only
Link Down: The system will send out an alert message when port connection is down
only
Link UP & Link Down: The system will send out an alert message when port
connection is up and down
After selected, click
Apply
Event Configuration interface