Cable Box User Manual

8
E-100BTX-FX-05
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Standard Models -- continued
E-100BTX-FX-05(XLW) 1550 nm single mode
Fiber-optic Transmitter Power: min: 0.0 dBm max: 5.0 dBm
Fiber-optic Receiver Sensitivity: min: -36.0 dBm max: -3.0 dBm
Link Budget: 36.0 dB
The fiber optic transmitters on this device meet Class I Laser safety requirements
per IEC-825/CDRH standards and comply with 21 CFR1040.10 and
21CFR1040.11.
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Fiber cable
Bit Error Rate: <10-9
Single mode fiber (recommended): 9 µm
Multimode fiber (recommended): 62.5/125 µm
Multimode fiber (optional): 100/140, 85/140, 50/125 µm
Extended temperature models
E-100BTX-FX-05(HT) 1300 nm multimode
Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm
Link Budget: 11.0 dB
E-100BTX-FX-05(SCHT) 1300 nm multimode
Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm
Link Budget: 11.0 dB
E-100BTX-FX-05(SMHT) 1310 nm single mode
Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm
Fiber-optic Receiver Sensitivity: min: -31.0 dBm max: -8.0 dBm
Link Budget: 16.0 dB
E-100BTX-FX-05(LHHT) 1310 nm single mode
Fiber-optic Transmitter Power: min: -8.0 dBm max: -2.0 dBm
Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm
Link Budget: 26.0 dB
E-100BTX-FX-05(XLHT) 1310 nm single mode
Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm
Fiber-optic Receiver Sensitivity: min: -38.0 dBm max: -8.0 dBm
Link Budget: 33.0 dB
E-100BTX-FX-05(LWHT) 1550 nm single mode
Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm
Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm
Link Budget: 29.0 dB
9
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Cable Specifications -- Continued
Copper cable
Category 5: (minimum requirement)
Gauge: 24 to 22 AWG
Attenuation: 22.0 dB /100m @ 100 MHz
Maximum Cable Distance: 100 meters
• Straight-through OR crossover cable may be used.
• Shielded twisted-pair (STP) OR unshielded twisted-pair (UTP) may be used
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Straight-Through Cable Crossover Cable
Twisted Pair #1
Twisted Pair #2
Twisted Pair #2
Twisted Pair #1
Technical Specifications
For use with Transition Networks Model E-100BTX-FX-05(xxxx) or equivalent
Standards: IEEE 802.3
Data rate: 100 Mb/s
Dimensions: 4.75" x 3.0" x 1.0" (119mm x 76mm x 25mm)
Weight: 6 oz. (181 g) approximate
MTBF 46,768 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
123,821 hours (Bellcore7 V5.0)
Power supply: (standard temperature) 12 VDC, 0.5 A (minimum)
DC output: (extended temperature) 9 VDC, 1.0 A (minimum)
minimum output regulation: 5%
Environment: Tmra* (standard temp): 0°C to 50°C (32 to 122°F)
Storage Temperature: -15°C to 65°C (5 to 149°F)
Tmra* (extended temp): -25°C to 65°C (-13 to 149°F)
Storage Temperature: -25°C to 65°C (5 to 149°F)
Humidity: 10% – 90%, non-condensing
Altitude: 0 to 10,000 feet
Warranty: Lifetime
*Manufacturer’s rated ambient temperature.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J
applicable at the date of manufacture.
CAUTION:
Visible and invisible laser radiation when open. Do not stare into beam or
view directly with optical instruments.
CAUTION:
Use of controls, adjustments or the performance of procedures other than
those specified herein may result in hazardous radiation exposure.