User Manual
Follow these instructions to clean the emitter points: 
1. Remove the front grill. 
2.   
 Moisten a swab or wiping cloth in the IPA solution. 
3.  Swab  or  wipe  the  emitter  points  until  they  are  free  of 
particles. 
4.  Make certain the emitter points are straight and parallel 
to the plane of the fan. 
5.  Replace the front grill.  
6.  Make sure the emitter points are dry before powering the 
ionizer again. 
Emitter Point Replacement 
  The IN5130 uses  tungsten alloy precision etched emit-
ter  needles.  Contact  Transforming  Technologies  for  infor-
mation about ordering replacement emitters. The part num-
ber for emitters is listed below: 
Replacement part      Part Number 
Tungsten replacement emitters    22-6423 
  Because the IN5130 high voltage output is AC, emitter 
erosion  from  the  ionization  process  on  the  electrodes  is 
minimal. Unless physically broken or stressed, the IN5130 
emitters should last the life of the ionizer. 
Follow these instructions to remove the emitter points: 
1.  Turn off and disconnect the unit from the AC power. 
2.  Remove the front grill. 
3.  Unscrew the threaded emitter point using a needle nose 
pliers. 
4.  Replace and tighten the new emitter using the same 
tool. Do not over-tighten. 
5.  Repeat steps 3 and 4 as required. 