  The red alarm indicator light illuminates in the event 
of a problem with the high voltage power output. 
  Turn the power switch off after operation. 
Maintenance 
Periodic Maintenance 
  The  only  regular  maintenance  required  for  the 
IN5130 is the periodic cleaning of the emitter points and 
ionizer grills. Emitter point cleaning affects the static de-
cay ability of the ionizer and is important for maintaining 
its optimal performance. 
Cleaning the front grill and external chassis 
 Disassemble the front grill by squeezing the grill side 
clips. Temporarily remove the grill. Clean it with a polyes-
ter wiper and a cleaning solution of 50% IPA (electronic-
grade isopropyl alcohol) and 50% de-ionized water. As-
semble it when it is dry. Use the same method to clean 
the exterior of the unit, including the inlet grill. 
Cleaning the emitter points 
  Contaminants will gradually accumulate on the tip 
of the emitter points with continuous use. Periodic clean-
ing of the emitter points is necessary to maintain the per-
formance  of  the  ionizer.  If  the  emitter  points  are  dirty, 
clean them with a polyester or cotton swab and IPA. Do 
not damage or loosen the emitter points. 
Caution 
! 
The only serviceable parts inside the ionizer are 
the replaceable emitter points. Any unauthor-
ized service will void the warranty and may 
result in additional repair fees. 