User Manual

6. Make certain the emitter points are straight and paral-
lel to the plane of the fan.
7. Replace the front grill.
Bracket Removal
The IN5120 in-tool ionizing blower can be removed
from the universal bracket by unscrewing the side knobs.
Note that there are washers located between the side
knobs, stand and chassis.
Service
Ptec™ ionizers are reliable products with a long ser-
vice life. If you feel your unit is not operating properly,
turn off the unit and disconnect the power cord. Contact
Transforming Technologies’ Technical Support for repair
assistance.
Troubleshooting
The information below provides a reference for prob-
lems that may arise with your IN5120 in-tool ionizing
blower. If you have other problems not covered below,
please contact Transforming Technologies’ Technical
Support for repair assistance
Problem Causes
Balance outside Emitter points are dirty, damaged
specifications. or not straight. Clean or replace
Alarm light activated Low HV output, call for repair
Unit is arcing, call for repair
Short circuit, call for repair