User Manual
Because the IN4000 high voltage output is AC, emitter erosion
from the ionization process on the electrodes is minimal.
Unless physically broken or stressed, the IN4000 emitters
should last the life of the ionizer.
Follow these instructions to remove the emitter points:
1. Turn off and disconnect the unit from the AC power.
2. Remove the output nozzle.
3. Unscrew the emitter point using needle nose pliers.
4. Replace and tighten the new emitter using the same tool.
Do not over-tighten.
5. Make certain the emitter points are straight and undam-
aged.
6. Replace the output nozzle.
Service
Ptec™ ionizers are reliable products with a long service
life. If you feel your unit is not operating properly, turn off the
unit and disconnect the power cord. Contact Transforming
Technologies’ Technical Support for repair assistance.
Troubleshooting
The information below provides a reference for problems
that may arise with your IN4000 ionizing air nozzle. If you
have other problems not covered below, please contact
Transforming Technologies’ Technical Support for repair as-
sistance
Problem Causes
Balance outside Emitter points are dirty, damaged
specifications. or not straight. Clean or replace
Alarm light activated Low HV output, call for repair
Unit is arcing, call for repair
Short circuit, call for repair