User Guide
Table Of Contents
- Contents
- Introduction to the Mercury6e- Transcore Module
- Functionality of the Embedded Modules
- Overview of the Communication Protocol
- Command Set
- Boot Loader Commands
- Multi-Protocol Tag Commands
- Allegro/Title-21 Tag Commands
- eGo/SeGo Tag Command Set
- ATA Tag Command Set
- Gen2 Tag Commands
- Get Configuration Commands
- Get Hardware Version (10h)
- Get Antenna Configuration (61h)
- Get Read TX Power (62h)
- Get Current Tag Protocol (63h)
- Get Write TX Power (64h)
- Get Frequency Hop Table (65h)
- Get User GPIO Inputs (66h)
- Get Current Region (67h)
- Get Power Mode (68h)
- Get User Mode (69h)
- Get Reader Configuration(6Ah)
- Get Protocol Configuration (6Bh)
- Get Reader Statistics (6Ch)
- Get Available Protocols (70h)
- Get Available Regions (71h)
- Get Current Temperature (72h)
- Set Configuration Commands
- FCC Test Commands
- Appendix A: Hardware Details
- Appendix B: Using the ArbSer Application
- Appendix C: Error Messages
- Common Error Messages
- FAULT_MSG_WRONG_NUMBER_OF_DATA – (100h)
- FAULT_INVALID_OPCODE – (101h)
- FAULT_UNIMPLEMENTED_OPCODE – 102h
- FAULT_MSG_POWER_TOO_HIGH – 103h
- FAULT_MSG_INVALID_FREQ_RECEIVED (104h)
- FAULT_MSG_INVALID_PARAMETER_VALUE - (105h)
- FAULT_MSG_POWER_TOO_LOW - (106h)
- FAULT_UNIMPLEMENTED_FEATURE - (109h)
- FAULT_INVALID_BAUD_RATE - (10Ah)
- Bootloader Faults
- FPGA Faults
- Flash Faults
- Protocol Faults
- FAULT_NO_TAGS_FOUND – (400h)
- FAULT_NO_PROTOCOL_DEFINED – 401h
- FAULT_INVALID_PROTOCOL_SPECIFIED – 402h
- FAULT_WRITE_PASSED_LOCK_FAILED – 403h
- FAULT_PROTOCOL_NO_DATA_READ – 404h
- FAULT_AFE_NOT_ON – 405h
- FAULT_PROTOCOL_WRITE_FAILED – 406h
- FAULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL – 407h
- FAULT_PROTOCOL_INVALID_WRITE_DATA – 408h
- FAULT_PROTOCOL_INVALID_ADDRESS – 409h
- FAULT_GENERAL_TAG_ERROR – 40Ah
- FAULT_DATA_TOO_LARGE – 40Bh
- FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch
- FAULT_PROTOCOL_KILL_FAILED - 40Eh
- FAULT_PROTOCOL_BIT_DECODING_FAILED - 40Fh
- FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
- FAULT_GEN2_PROTOCOL_MEMORY_OVERRUN_BAD_PC - 423h
- FAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424h
- FAULT_GEN2 PROTOCOL_INSUFFICIENT_POWER - 42Bh
- FAULT_GEN2 PROTOCOL_NON_SPECIFIC_ERROR - 42Fh
- FAULT_GEN2 PROTOCOL_UNKNOWN_ERROR - 430h
- Analog Hardware Abstraction Layer Faults
- Tag ID Buffer Faults
- System Errors
- Common Error Messages
- Appendix D: FPGA Support
eGo/SeGo Tag Command Set
86
Examples
An example command requesting :
Command Type 0x00 Performs a QueryLock, immediate followed by an UnLock
0x01 Performs a QueryLock, immediate followed by a Lock
0x0F LockByte operation. Performs QLock/Lock/QLock
0x10 UnLock Byte. Performs QLock/UnLock/QLock
0x11 QueryLock
0x8F Lock Page. Performs QLock/Lock/QLock
0x90 UnLock Page. Performs QLock/UnLock/QLock
Lock Address [1 byte] Indicates the address of tag memory to be (un)locked.
Tag ID [8 byte] Indicates the Tag ID of the tag to be (un)locked.
Key Address [1 byte] Only passed when authentication enabled in TM Options.
Key Length in Bytes [1 byte] Only passed when authentication enabled in TM Options.
Key [0-N bytes] Only passed when authentication enabled in TM Options.
Note: Value passed with MSB first.
FF 0D 25 ?? ?? 01 0F ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ??
SOH Length OpCode Timeout
(ms)
TM
Option
Command
Type
Lock
Address
Tag ID CRC
Field Value Description