Solution
Check the HW specifications for the supported powers and insure that level is not
exceeded. The M5e supports powers between 5 and 30 dBm. The M5e-Compact units
support power from 10 dBm to 23 dBm.
FAULT_UNIMPLEMENTED_FEATURE - (109h)
Cause
Attempting to invoke a command not supported on this firmware or hardware.
Solution
Check the command being invoked against the documentation.
FAULT_INVALID_BAUD_RATE - (10Ah)
Cause
When a Set Baud Rate (0x06h) command is issued for a rate that is not specified in the
Baud Rate table, this error message is returned.
Solution
Check the table of specific baud rates and select a baud rate. Send the baud rate in the
hex format. See Set Baud Rate (06h)
.