User Guide
Table Of Contents
- Contents
- Introduction to the Mercury6e- Transcore Module
- Functionality of the Embedded Modules
- Overview of the Communication Protocol
- Command Set
- Boot Loader Commands
- Multi-Protocol Tag Commands
- Allegro/Title-21 Tag Commands
- eGo/SeGo Tag Command Set
- ATA Tag Command Set
- Gen2 Tag Commands
- Get Configuration Commands
- Get Hardware Version (10h)
- Get Antenna Configuration (61h)
- Get Read TX Power (62h)
- Get Current Tag Protocol (63h)
- Get Write TX Power (64h)
- Get Frequency Hop Table (65h)
- Get User GPIO Inputs (66h)
- Get Current Region (67h)
- Get Power Mode (68h)
- Get User Mode (69h)
- Get Reader Configuration(6Ah)
- Get Protocol Configuration (6Bh)
- Get Reader Statistics (6Ch)
- Get Available Protocols (70h)
- Get Available Regions (71h)
- Get Current Temperature (72h)
- Set Configuration Commands
- FCC Test Commands
- Appendix A: Hardware Details
- Appendix B: Using the ArbSer Application
- Appendix C: Error Messages
- Common Error Messages
- FAULT_MSG_WRONG_NUMBER_OF_DATA – (100h)
- FAULT_INVALID_OPCODE – (101h)
- FAULT_UNIMPLEMENTED_OPCODE – 102h
- FAULT_MSG_POWER_TOO_HIGH – 103h
- FAULT_MSG_INVALID_FREQ_RECEIVED (104h)
- FAULT_MSG_INVALID_PARAMETER_VALUE - (105h)
- FAULT_MSG_POWER_TOO_LOW - (106h)
- FAULT_UNIMPLEMENTED_FEATURE - (109h)
- FAULT_INVALID_BAUD_RATE - (10Ah)
- Bootloader Faults
- FPGA Faults
- Flash Faults
- Protocol Faults
- FAULT_NO_TAGS_FOUND – (400h)
- FAULT_NO_PROTOCOL_DEFINED – 401h
- FAULT_INVALID_PROTOCOL_SPECIFIED – 402h
- FAULT_WRITE_PASSED_LOCK_FAILED – 403h
- FAULT_PROTOCOL_NO_DATA_READ – 404h
- FAULT_AFE_NOT_ON – 405h
- FAULT_PROTOCOL_WRITE_FAILED – 406h
- FAULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL – 407h
- FAULT_PROTOCOL_INVALID_WRITE_DATA – 408h
- FAULT_PROTOCOL_INVALID_ADDRESS – 409h
- FAULT_GENERAL_TAG_ERROR – 40Ah
- FAULT_DATA_TOO_LARGE – 40Bh
- FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch
- FAULT_PROTOCOL_KILL_FAILED - 40Eh
- FAULT_PROTOCOL_BIT_DECODING_FAILED - 40Fh
- FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
- FAULT_GEN2_PROTOCOL_MEMORY_OVERRUN_BAD_PC - 423h
- FAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424h
- FAULT_GEN2 PROTOCOL_INSUFFICIENT_POWER - 42Bh
- FAULT_GEN2 PROTOCOL_NON_SPECIFIC_ERROR - 42Fh
- FAULT_GEN2 PROTOCOL_UNKNOWN_ERROR - 430h
- Analog Hardware Abstraction Layer Faults
- Tag ID Buffer Faults
- System Errors
- Common Error Messages
- Appendix D: FPGA Support
Set Configuration Commands
155
Note
When LBT is disabled in the Open region the M6e-TC will implement
frequency hopping as implemented for the NA region with a frequency hop
interval of 400ms.
Set Power Mode (98h)
The Set Power Mode command can set the M6e-TC to four different power
management modes. See Available power modes
.
Use the Set Power Mode command to set the power mode to maximum saving mode by
sending the following:
Set User Mode (99h)
Use the Set User Mode command to set the user mode to the type of application in
which the M6e-TC will be configured for the optimal Search Strategy settings for a
particular protocol.
Send the following to set the user mode to printer:
The list of user modes and their corresponding session are found in Available User Modes
.
Setting the User Mode to an unsupported value will not modify the current setting.
Set Reader Configuration(9Ah)
The Set Reader Configuration command is used to set several configuration options on
the reader. The configuration options, defined in the table below are enabled bitwise,
although the option value is specified in hexidecimal (2 bytes). One example
configuration and the corresponding Options value is specified in the command example
below. For other combinations the hex value for Options will need to be calculated by
OR’ing the bits for each setting.
FF 01 98 03 44 BE
SOH Length OpCode Power Mode CRC
FF 01 99 01 45 BC
SOH Length OpCode User Mode CRC