User Guide

Table Of Contents
Get Configuration Commands
135
Get Configuration Commands
The Get commands listed in the following table are used to get settable parameters from
the Mercury Embedded module. All of the commands have a data length of zero, and
return data or a fault code. These commands cannot be run in the Bootloader.
Get Configuration Commands
OpCode Command Name Arguments Return
0x10
Get Hardware Version (10h)
Option, Mask Hardware Information
0x61
Get Antenna Configuration (61h)
Option Antenna configuration
0x62
Get Read TX Power (62h)
Return Option (1
byte)
Read TX Power Setting
(and optionally Min. and
Max power)
0x63
Get Current Tag Protocol (63h)
none Current Tag Protocol
0x64
Get Write TX Power (64h)
none Write TX Power Setting
0x65
Get Frequency Hop Table (65h)
none Current Frequency Hop
Ta ble
0x66
Get User GPIO Inputs (66h)
none GPIO Input Data
0x67
Get Current Region (67h)
none Current region being used
0x68
Get Power Mode (68h)
none Current power mode setting
0x69
Get User Mode (69h)
none Current user mode setting
0x6A
Get Reader Configuration(6Ah)
none Current reader configuration
options set
0x6B
Get Protocol Configuration (6Bh)
Protocol, Parame-
ter (2 bytes)
Parameter Value
0x6C
Get Reader Statistics (6Ch)
Option, Statistics Reader Statistics
0x70
Get Available Protocols (70h)
none Available Protocols
0x71
Get Available Regions (71h)
none Available regions.
0x72
Get Current Temperature (72h)
none Current module tempera-
ture