User Guide

Table Of Contents
Gen2 Tag Commands
126
Alien Higgs Sub Commands
Partial Load Image
Sub Command=0x01
If the first bit of Sub Command is 1 (Sub Command=0x01), the Gen2 Tag Specific
command writes an EPC with a length of up to 96-bits, plus the Kill and Access
passwords without locking in a single command.
The format for this command is as follows:
Sub Command value
Alien Higgs
Command
0x01
Partial Load Image
0x03
Full Load Image
FF 18 2D 03 E8 01 01 00 00 00 00 00 00 00 00
SO
H
Length OpCode Timeout (ms) Chip Type Sub
Com-
mand
Kill Password Access Password
11 22 33 44 55 66 77 88 99 AA BB CC 45 64
Tag ID CRC