User Guide

Table Of Contents
eGo/SeGo Tag Command Set
91
Examples
An example command requesting :
ACK Response
When Command Type = 0x80
Tag ID | Select Data [8 bytes] When:
• Command Type = 0x0B, 0x0C, 0x12 or 0x92:
8 bytes = Tag ID
• Command Type = 0x80
[1 byte] = Select Address
[1 byte] = Select Data
[6 bytes] = RFU
Key Address [1 byte] Only passed when authentication enabled by TM Options.
Key Length in Bytes [1 byte] Only passed when authentication enabled by TM Options.
Key [0-N bytes] Only passed when authentication enabled by TM Options.
Note: Value passed with MSB first.
FF 0F 28 ?? ?? 01 0C ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ??
SOH Length OpCode Timeout
(ms)
TM
Option
Command
Type
RFU Read
Byte
Count
Read
Address
Tag ID CRC
FF ?? 28 ?? ?? 01 0C ?? ?? ??
SOH Length OpCode Status TM
Option
Command
Type
Read
Data
CRC
FF ?? 28 ?? ?? ?? 80 ??
?? ?? ?? ??
?? ?? ?? ??
?? ?? ?? ??
?? ?? ?? ??
?? ??
SOH Length OpCode Status TM
Option
Command
Type
Tag ID
Length
Tag ID (length
defined by ID
Length)
Read Data CRC
Field Value Description