User Guide
Table Of Contents
- Contents
- Contents
- Introduction to the Mercury6e- Transcore Module
- Functionality of the Embedded Modules
- Overview of the Communication Protocol
- Command Set
- Boot Loader Commands
- Multi-Protocol Tag Commands
- Allegro/Title-21 Tag Commands
- eGo/SeGo Tag Command Set
- ATA Tag Command Set
- Gen2 Tag Commands
- Get Configuration Commands
- Get Hardware Version (10h)
- Get Antenna Configuration (61h)
- Get Read TX Power (62h)
- Get Current Tag Protocol (63h)
- Get Write TX Power (64h)
- Get Frequency Hop Table (65h)
- Get User GPIO Inputs (66h)
- Get Current Region (67h)
- Get Power Mode (68h)
- Get User Mode (69h)
- Get Reader Configuration(6Ah)
- Get Protocol Configuration (6Bh)
- Get Reader Statistics (6Ch)
- Get Available Protocols (70h)
- Get Available Regions (71h)
- Get Current Temperature (72h)
- Set Configuration Commands
- Regulatory Test Commands
- Appendix A: Hardware Details
- Appendix B: Using the ArbSer Application
- Appendix C: Error Messages
- Common Error Messages
- FAULT_MSG_WRONG_NUMBER_OF_DATA – (100h)
- FAULT_INVALID_OPCODE – (101h)
- FAULT_UNIMPLEMENTED_OPCODE – 102h
- FAULT_MSG_POWER_TOO_HIGH – 103h
- FAULT_MSG_INVALID_FREQ_RECEIVED (104h)
- FAULT_MSG_INVALID_PARAMETER_VALUE - (105h)
- FAULT_MSG_POWER_TOO_LOW - (106h)
- FAULT_UNIMPLEMENTED_FEATURE - (109h)
- FAULT_INVALID_BAUD_RATE - (10Ah)
- Bootloader Faults
- FPGA Faults
- Flash Faults
- Protocol Faults
- FAULT_NO_TAGS_FOUND – (400h)
- FAULT_NO_PROTOCOL_DEFINED – 401h
- FAULT_INVALID_PROTOCOL_SPECIFIED – 402h
- FAULT_WRITE_PASSED_LOCK_FAILED – 403h
- FAULT_PROTOCOL_NO_DATA_READ – 404h
- FAULT_AFE_NOT_ON – 405h
- FAULT_PROTOCOL_WRITE_FAILED – 406h
- FAULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL – 407h
- FAULT_PROTOCOL_INVALID_WRITE_DATA – 408h
- FAULT_PROTOCOL_INVALID_ADDRESS – 409h
- FAULT_GENERAL_TAG_ERROR – 40Ah
- FAULT_DATA_TOO_LARGE – 40Bh
- FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch
- FAULT_PROTOCOL_KILL_FAILED - 40Eh
- FAULT_PROTOCOL_BIT_DECODING_FAILED - 40Fh
- FAULT_PROTOCOL_INVALID_EPC – 410h
- FAULT_PROTOCOL_INVALID_NUM_DATA – 411h
- FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
- FAULT_GEN2_PROTOCOL_MEMORY_OVERRUN_BAD_PC - 423h
- FAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424h
- FAULT_GEN2 PROTOCOL_INSUFFICIENT_POWER - 42Bh
- FAULT_GEN2 PROTOCOL_NON_SPECIFIC_ERROR - 42Fh
- FAULT_GEN2 PROTOCOL_UNKNOWN_ERROR - 430h
- Analog Hardware Abstraction Layer Faults
- Tag ID Buffer Faults
- System Errors
- Common Error Messages
- Appendix D: FPGA Support
Allegro/Title-21 Tag Commands
72
ACK Response
NACK Response
No Response
Random Number Request (28h; D001h)
The Random Number Request command requests a 32-bit random number from the
specified tag which is used in the P/W authentication scheme. This command also
specifies which page is to be read or written to with the encrypted P/W on the next cycle.
This command contains the following request fields:
FF ?? + N 28 00 00 00 C0 03 ?? ?? ?? ?? ?? ?? ?? ?? .. .. ?? NN NN ?? ??
SOH Length TM
OpCode
Status TM
Option
Transac-
tion Type
Code
Options Tag ID Page
Number
AntiPlay-
Back
(0, 1, 2)
[Based
on
Options]
Page
Count
Page Data CRC
FF 0B 28 04 0A 00 C0 03 ?? ?? ?? ?? ?? ?? ??
SOH Length TM
OpCode
Status TM
Option
Transaction
Type Code
Options Tag ID CRC
FF 00 28 04 00 25 AA
SOH Length TM
OpCode
Status CRC