30 Functionality of the Embedded Modules
configure the communications protocol. In order to use the USB interface with Windows
you must have the m6etc.inf file. The installation steps are:
1. Plug in the USB cable to the M6e-TC (devkit) and PC.
2. Windows should report “Found New Hardware - M6e-TC Serial” and open the
Hardware Installation Wizard.
3. Select the Install from a list or specific location (Advanced) option, click Next.
4. Select Don’t search..., click Next, then Next again.
5. Click Have Disk and navigate to where the m6etc.inf file is stored; select it, click
Open, then OK.
6. “Mercury6eTC” should now be shown under the Model list. Select it and click Next
then Finished.
Note
The M6e-TC driver file has not been Microsoft certified so compatibility
warnings will be displayed. These can be ignored and clicked through.
7. A COM port should now be assigned to the M6e-TC. If you aren’t sure what COM
port is assigned you can find it using the Windows Device Manager:
a. Open the Device Manager (located in Control Panel | System).
b. Select the Hardware tab and click Device Manager.
c. Select View | Devices by Type | Ports (COM & LPT)
The device appears as Mercury6eTC (COM#).
General Purpose Inputs/Outputs (GPIO)
The M6e-TC modules has four TTL level signals, two 3.3/5V serial input sensor ports
(GPIO inputs) and two output indicator ports (GPIO outputs) of up to 24 mA, available on
the 14-pin digital connector. These can be controlled via the Get User GPIO Inputs and
Set User GPIO Outputs commands.
For further information, see
Get User GPIO Inputs (66h) and Set User GPIO Outputs (96h).