User Guide
Table Of Contents
- Contents
- Contents
- Introduction to the Mercury6e- Transcore Module
- Functionality of the Embedded Modules
- Overview of the Communication Protocol
- Command Set
- Boot Loader Commands
- Multi-Protocol Tag Commands
- Allegro/Title-21 Tag Commands
- eGo/SeGo Tag Command Set
- ATA Tag Command Set
- Gen2 Tag Commands
- Get Configuration Commands
- Get Hardware Version (10h)
- Get Antenna Configuration (61h)
- Get Read TX Power (62h)
- Get Current Tag Protocol (63h)
- Get Write TX Power (64h)
- Get Frequency Hop Table (65h)
- Get User GPIO Inputs (66h)
- Get Current Region (67h)
- Get Power Mode (68h)
- Get User Mode (69h)
- Get Reader Configuration(6Ah)
- Get Protocol Configuration (6Bh)
- Get Reader Statistics (6Ch)
- Get Available Protocols (70h)
- Get Available Regions (71h)
- Get Current Temperature (72h)
- Set Configuration Commands
- Regulatory Test Commands
- Appendix A: Hardware Details
- Appendix B: Using the ArbSer Application
- Appendix C: Error Messages
- Common Error Messages
- FAULT_MSG_WRONG_NUMBER_OF_DATA – (100h)
- FAULT_INVALID_OPCODE – (101h)
- FAULT_UNIMPLEMENTED_OPCODE – 102h
- FAULT_MSG_POWER_TOO_HIGH – 103h
- FAULT_MSG_INVALID_FREQ_RECEIVED (104h)
- FAULT_MSG_INVALID_PARAMETER_VALUE - (105h)
- FAULT_MSG_POWER_TOO_LOW - (106h)
- FAULT_UNIMPLEMENTED_FEATURE - (109h)
- FAULT_INVALID_BAUD_RATE - (10Ah)
- Bootloader Faults
- FPGA Faults
- Flash Faults
- Protocol Faults
- FAULT_NO_TAGS_FOUND – (400h)
- FAULT_NO_PROTOCOL_DEFINED – 401h
- FAULT_INVALID_PROTOCOL_SPECIFIED – 402h
- FAULT_WRITE_PASSED_LOCK_FAILED – 403h
- FAULT_PROTOCOL_NO_DATA_READ – 404h
- FAULT_AFE_NOT_ON – 405h
- FAULT_PROTOCOL_WRITE_FAILED – 406h
- FAULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL – 407h
- FAULT_PROTOCOL_INVALID_WRITE_DATA – 408h
- FAULT_PROTOCOL_INVALID_ADDRESS – 409h
- FAULT_GENERAL_TAG_ERROR – 40Ah
- FAULT_DATA_TOO_LARGE – 40Bh
- FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch
- FAULT_PROTOCOL_KILL_FAILED - 40Eh
- FAULT_PROTOCOL_BIT_DECODING_FAILED - 40Fh
- FAULT_PROTOCOL_INVALID_EPC – 410h
- FAULT_PROTOCOL_INVALID_NUM_DATA – 411h
- FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
- FAULT_GEN2_PROTOCOL_MEMORY_OVERRUN_BAD_PC - 423h
- FAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424h
- FAULT_GEN2 PROTOCOL_INSUFFICIENT_POWER - 42Bh
- FAULT_GEN2 PROTOCOL_NON_SPECIFIC_ERROR - 42Fh
- FAULT_GEN2 PROTOCOL_UNKNOWN_ERROR - 430h
- Analog Hardware Abstraction Layer Faults
- Tag ID Buffer Faults
- System Errors
- Common Error Messages
- Appendix D: FPGA Support
Set Configuration Commands
159
Available Configuration Options
Send the following to enable the 496 bit EPC mode:
Note
Multiple settings cannot be applied in a single command.
Set Protocol Configuration (9Bh)
The Set Protocol Configuration command is used to set protocol-specific configuration
parameters. The table below defines the currently available protocol-specific parameters
which can be set and the supported settings. Additional parameters will be supported in
the future.
Option Key Value Reader Configuration setting
0x00 Indicates the deprecated format of this command will be used.
0x01 Maximum EPC Length
= 0x02
0x00 Maximum EPC length of 96 bits (Default)
0x01 Maximum EPC length of 496 bits
Record the highest RSSI
seen
= 0x06
0x00
The RSSI Tag Read Meta Data value is the value for the
last read tag for each tag buffer entry when this is Dis-
abled. (Default)
0x01
When Enabled the RSSI Tag Read Meta Data value will
be the highest value recorded during the Read Tag Multi-
ple (22h) search operation.
PA Protection
= 0x07
Note: Not available in
firmware v1.13 and later.
0x00
Disable - Turns off Power Amplifier Protection.
NOT RECOMMENDED.
0x01 Enable (Default)
Tag Data as Unique Iden-
tifier of Tag Buffer entry.
= 0x08
0x00 Tag Data is a unique characteristic of a Tag Buffer
Entry.
0x01 Tag Data is ignored for Tag Buffer Entry uniqueness
(Default)
FF 03 9A 01 02 01 AD 5C
SOH Length OpCode Option Key Value CRC