User Guide

Table Of Contents
Get Configuration Commands
145
Note
If
Set Power Mode (98h) is called using the USB interface and mode 0x03 is
specified the module will instead be set to 0x02. In order to set the module to
mode 0x03 the command must be called using the RS232 interface.
The command gets the current power mode setting from the module:
The example reply shows that the system is in the medium power saving mode:
Get User Mode (69h)
The Get User Mode command returns the type of application in which the M5e/M5e-
Compact can be used. The available user modes are shown in the table:
Available User Modes
The command gets the current user mode setting from the module:
FF 00 68 1D 67
SOH Length OpCode CRC
FF 01 68 00 00 02 A4 BD
SOH Length OpCode Status Power Mode CRC
Hex User Mode
0x00 NONE (Default)
0x01 PRINTER
0x02 Unsupported
0x03 PORTAL
0x04 HAND HELD