Data Sheet
4.1.3 Power On or Power Cycle 
Followings are requirements for Power on and Power cycle to assure a reliable SD Card hard reset. 
(1) Voltage level shall be below 0.5V 
(2) Duration shall be at least 1ms. 
4.1.4 Power Supply Ramp Up 
The power ramp up time is defined from 0.5V threshold level up to the operating supply voltage which is 
stable between VDD(min.) and VDD(max.) and host can supply SDCLK. 
Followings are recommendation of Power ramp up: 
(1) Voltage of power ramp up should be monotonic as much as possible. 
(2) The minimum ramp up time should be 0.1ms. 
(3) The maximum ramp up time should be 35ms for 2.7-3.6V power supply. 
(4) Host shall wait until VDD is stable. 
(5) After 1ms VDD stable time, host provides at least 74 clocks before issuing the first command. 
4.1.5 Power Down and Power Cycle 
  When  the  host  shuts down  the  power, the  card  VDD  shall  be  lowered  to  less than  0.5Volt for  a  minimum 
period of 1ms. During power  down, DAT,  CMD, and CLK should be disconnected or driven to logical 0 by the 
host to avoid a situation that the operating current is drawn through the signal lines. 
 If the host needs to change the operating voltage, a power cycle is required. Power cycle means the power is 
turned off and supplied again. Power cycle is also needed for accessing cards that are already in Inactive State. 
To create a power cycle the host shall follow  the power down description before power up  the card (i.e. the 
card VDD shall be once lowered to less than 0.5Volt for a minimum period of 1ms). 