144PIN PC133 Unbuffered SO-DIMM
512MB With 32M X 8 CL3
AC OPERATING TEST CONDITIONS (VDD = 3.3V ± 0.3V, TA = 0 to 65°C)
Parameter Value Unit
AC Input levels (V
IH
/V
IL
) 2.4/0.4 V
Input timing measurement reference level 1.4 V
Input rise and fall time tr/tf=1/1 ns
Output timing measurement reference level 1.4 V
Output load condition See Fig. 2
Output
(Fig. 1) DC Output Load Circuit
3.3V
1200 Ohm
50pF
870 Ohm
V
OH
(DC)=2.4V, I
OH
=-2mA
V
OL
(DC)=0.4V, I
OL
=2mA
Output
(Fig. 2) AC Output Load Circuit
Vtt=1.4V
50 Ohm
50pF
Z0=50 Ohm
AC Characteristics (TA = 0 to 65°C, VDD = 3.3V ± 0.3V, Vss= 0V)
Parameter
Symbol
Value
Unit
Note
System clock cycle time
t
CK
7.5 ns 1
CK high pulse width
t
CKH
2.5 ns 1
CK low pulse width
t
CKL
(min)
2.5 ns 1
Access time from CK
t
AC
5.4 ns 1,2
Data-out hold time
t
OH
3.0 ns 1,2
CK to Data-out low impedance
t
LZ
0.0 ns 1,2
CK to Data-out high impedance
t
HZ
3.0 ns 1
Input setup time
T
AS,
t
CS,
t
DS,
t
CES
1.5 ns 1
CKE setup time for power down exit
t
CESP
2.0 ns 1
Input hold time
T
AH,
t
CH,
t
DH,
t
CEH
0.8 ns 1
Ref/Active to Ref/Active command period
T
RC (
min
)
70.0 ns 1
Active to precharge command period
T
RAS
(min)
45.0 ns 1
Active command to column command (same bank)
t
RCD
20.0 ns 1
Precharge to active command period
t
RP
20.0 ns 1
Write recovery or data-in to precharge lead time
t
DPL
15.0 ns 1
Active (a) to Active (b) command period
t
RRD
15.0 ns 1
Transition time (rise and fall)
t
T
(min)
1.0 ns
Refresh period
T
REF (max)
64.0 ms
Note:
1. AC measurement assumes t
T
= 1ns. Reference level for timing of input signals is 1.5V.
2. Access time is measured at 1.5V. Load condition is C
L
= 50 pF
Transcend information Inc.
7