Data Sheet
SMART RETURN STATUS
B0h with a Feature register value of DAh. This command causes the device to communicate the reliability status of the
device to the host. If a threshold exceeded condition is not detected by the device, the device shall set the LBA Mid register
to 4Fh and the LBA High register to C2h. If a threshold exceeded condition is detected by the device, the device shall set
the LBA Mid register to F4h and the LBA High register to 2Ch.
SMART Read Data
B0h with the content of the Features register equal to D0h. This command returns the Device SMART data structure to
the host.