Brochure
Table Of Contents
19
Safety
I
Transair
®
aluminium range can be used for vacuum applications down to
10 mbar absolute pressure.
I
Transair
®
aluminium range is suitable for distribution of non
flammable gases such as: Argon, Nitrogen, Carbon Dioxyde and
mix of these gases. Based on laboratory purity testing, Transair
®
(fitting and aluminium piping) is compatible with 99.99% purity
Nitrogen applications.
®
Nitrogen (N
2
) Compatible
Argon Compatible
Carbon Dioxyde (C0
2
) Compatible
Helium (He
2
) Compatible
Mix Argon (Ar
2
) +
Carbon Dioxyde (CO
2)
All ratios
Oxygen (O
2
) Up to 22%
Hydrogen (H
2
) Up to 4%
I
Transair
®
aluminium range is classified B s2 d0 according to EN 13501-1.
EN 13501-1 certification describes the different classes of reaction to fire for the 3 main criteria as fol-
lows: energy contribution to the propagation of fire, smoke production and flaming particles.
I Transair
®
Transair
®
blowgun EA59 00 13 complies with regulations OSHA 1910.242 (b) for hand and portable
powered tools, OSHA 1910.95 (b), Directive 2003/10/EC.
The above mentioned certificates are available upon request.
Transair
®
aluminium range is compatible with transportation of above
gas, according to all recommendations of uses of Transair
®
piping sys-
tem, provided the conveyed uid is dry (no condensation in the Transair
®
piping system).
B
Contribution
limited to fire
propagation
Resistant to prolonged
attack flames and
ardent isolated object
while limiting the
spread of flame.
s2
Average smoke
production
d0
no drops,
no flaming
particles