Brochure

15
164ft 328ft 492ft 984ft 1640ft 2460ft 3280ft 4265ft 5249ft 6561ft
Nm
3
/h Nl/min cfm 50m 100m 150m 300m 500m 750m 1000m 1300m 1600m 2000m
10 167 6 16.5 16.5 16.5 16.5 25 25 25 25 25 25 1
30 500 18 16.5 25 25 25 25 40 40 40 40 40 3
50 833 29 25 25 25 40 40 40 40 40 40 40 5.5
70 1167 41 25 25 25 40 40 40 40 40 40 40 7.5
100 1667 59 25 40 40 40 40 40 40 50 50 50 11
150 2500 88 40 40 40 40 40 50 50 50 50 63 15
250 4167 147 40 40 40 50 50 63 63 63 63 76 25
350 5833 206 40 40 50 50 63 63 63 76 76 76 30
500 8333 294 40 50 50 63 63 76 76 76 100 100 45
750 12500 441 50 63 63 76 76 100 100 100 100 100 75
1000 16667 589 50 63 76 76 100 100 100 100 100 168 90
1250 20833 736 63 76 76 100 100 100 100 168 168 168 110
1500 25000 883 63 76 76 100 100 100 168 168 168 168 132
1750 29167 1030 76 76 100 100 100 168 168 168 168 168 160
2000 33333 1177 76 76 100 100 168 168 168 168 168 168 200
2500 41667 1471 76 100 100 100 168 168 168 168 168 168 250
3000 50000 1766 100 100 100 168 168 168 168 168 168 168 315
3500 58333 2060 100 100 100 168 168 168 168 168 168 168 355
4000 66667 2354 100 100 168 168 168 168 168 168 168 168 400
4500 75000 2649 100 100 168 168 168 168 168 168 168 168 450
5000 83333 2943 100 168 168 168 168 168 168 168 168 168 500
5500 91667 3237 100 168 168 168 168 168 168 168 168 168 550
6000 100000 3531 100 168 168 168 168 168 168 168 168 168 600
6500 108333 3826 168 168 168 168 168 168 168 168 168 168 650
7000 116667 4120 168 168 168 168 168 168 168 168 168 168 700
Sizing
I 
Select the Transair
®
diameter for your application based on required flow and length.Estimated values for a closed
loop network, a pressure of 8 bar with 5% pressure drop.Velocity is not taken into account.

 

