Brochure

145
Ø 76
Ø 100
41
3
2
1 2
3
4
5
6
2 - Connect the pipe
1 - Slip the cartridge over the end of the first
pipe fully up to the shoulder.
2 - Bring the second pipe to the cartridge and
slide fully up to the shoulder.
3 - Position the clamp over the cartridge / pipe
assembly.
4 - Hand tighten the pre-fitted screws with a 6mm
Allen key.
5 - Pull the pipes fully back towards the outside
of the clamp.
6 - Tighten the clamp screws as follows:
- mini tightening torque: 10 N.m
- maxi tightening torque: make the 2
clamps touch together
7 - For effective clamp sealing, screw tighte
ning should be performed on alternate
sides of the clamp as shown above.
For effective clamp sealing, screw tightening should be performed on alternate sides of the clamp
as shown below:
To disconnect, perform the same operations in reverse order.
Connection / Disconnection
INSTALLATION GUIDE