Installation Guide
Table Of Contents
- Table 1: Revision History
- DR5000 Reader Installation Guide
- Mounting Options
- Figure 1-3 Figure 1-3 DR5000 Mounting Options
- Detailed Installation
- 1 For installations without a trim plate, use the mounting plate as a guide to drill mounting holes and cable route opening in the mounting surface.
- 2 Route cable through opening or to the single gang box, see wiring tables on step 6.
- 3 Install the trim plate if applicable.
- 4 Install the mounting plate.
- 5 Connect the wires to the terminal blocks. Refer to tables 2 and 3 for wiring connections.
- Table 1-2: Figure 1-5 TB1 Connections
- Table 1-3: Figure 1-6 TB2 Connections
- 6 Plug the terminal block(s) onto the pins of the DR5000 Reader; and the terminal blocks in the proper locations.
- 7 Place the reader just above the mounting plate, and then slide down to engage the tab into notch on the back of the reader.
- 8 Secure reader using the tamper resistant security screw (3/32" tamper hex).
- Figure 1-4 Figure 1-8 Tamper Resistant Security Screw
- Reader Configuration
- Reader Testing
- Troubleshooting
- Specifications
DR5000 READER INSTALLATION GUIDE
2
403-003-001 Rev A
DR5000 READER INSTALLATION GUIDE
DR5000 Readers is designed to work with Transact SA3000 Door Access and third- party Access Control
systems that use a Wiegand interface.
DR5000 Readers support contactless cards using Near Field Communications (NFC) compatible technology.
When a contactless card is within range (1.5 inches or less) from the front of the reader, data on the card is
read. Card account numbers are stored as up to 48 ASCII numerical digits on the contactless card.
Figure 1-1 DR5000 Reader
Reader Installation Overview
When choosing a location to install a DR5000 series reader, consider
the following:
•Proximity to entry point
• Visibility and Access to Users
• ADA Requirements
• Protection of the reader from environmental elements
• Cable distance/path to access panel
• 1200 ft. maximum for RS-485 to Transact SA3032
• 500 ft. maximum for Wiegand interface
Shown with optional trim plate