Trango Systems, Inc. StrataPro 24 Quick Start Guide 9
INSTALLATION REQUIREMENTS
TOOLS
- Flat head Screwdriver for port cover attachment
- 13 mm or ½” Socket wrench for standard mount assembly
- 8 mm or 5/16” Socket wrench for attaching radio to mount and ground lug.
- Multimeter with CABLDAT-RSSI for antenna alignment
PATH
- Line of sight (LOS) with no obstructions in the Fresnel Zone
-
MOUNTING STRUCTURE
- Building or 1.5 to 3 inch diameter pole with < 1.5 degrees vertical or horizontal
movement under windload.
- Radios must be mounted at least 8 feet off the ground for best performance
POWER
- 110 or 240 VAC if using PoE Adapter
- +43 to +57 VDC/1.5 Amp Regulated Power Supply if using direct input
GROUNDING
- Min 10 AWG grounding cable with #10 Spade Lug, maximum length 1 m/3 feet
CABLING
- Cat 5e or Cat6 Shielded Twisted pair with shielded plugs. The cable shield should
be electrically connected to the plug shell. If using PoE the cable to the radio
should be no longer that 250 feet total.
SYSTEM CONFIGURATION:
The radios come preconfigured from the factory and will link up with no change to user
settings. The only change that must be made is to set the static IP address of the radios.
Follow the steps below to set the IP address and verify the RF link before installation.
1) Apply power using the PoE or with direct power (+56VDC)
2) Set up a Personal computer which has it’s local IP and subnet mask set as
follows:
IP: 192.168.100.10
Subnet: 255.255.255.0
Gateway: 192.168.100.1