Link LED Green LED is solid on when linked with the far end unit, and Flashing when
not linked. LED will be solid at system power up for up to 2 minutes.
RSSI LEDs Amber LEDs are lit up based on the M1 RSSI according to the following
table:
0 LEDs: RSSI < -65 dBm
1 LED: RSSI > -65 dBm
2 LEDs: RSSI > -60 dBm
3 LEDs: RSSI > -55 dBm
4 LEDs: RSSI > -50 dBm
5 LEDs: RSSI > -45 dBm
6 LEDs: RSSI > -40 dBm
Xin/Xout (XI model only) Input/Output coaxial connection to second MIMO radio for
use in 4x4 MIMO configuration Radios must be spaced at the optimum distance for
proper operation (See manual for details). CBLDAT-MIMO-9 kit required for spacings up
to 3 meters. Connect Xin to Xout on second radio.
USB Port Reserved for Future Use - Do not connect
1+1 1+1 Hot Standby port for monitoring connection to Hot Standby Radio. The
Standby unit should be as close as possible to the Active Unit and aligned with the far
end. CBLDAT-RIU5 cable required for each end of link.
Note that this cable carries monitoring information for the Standby unit to determine if
the Active unit is operating properly. If the cable is removed during operation then the
Standby will activate. Ensure that the cable is securely installed. See Full User Manual for
more details.