BNC Output of DC voltage proportional to the RSSI level. The chart below gives the
voltage vs RSL.
BNC Connector w/Cap
The BNC Voltage = 0.1 +0.04 x (90+RSL) Volts, where RSL = -90 to -20 dBm
RSL(dBm) -90 -85 -80 -75 -70 -65 -60 -55 -50 -45 -40 -35 -30 -25 -20
BNC Voltage (V) 0.10 0.30 0.50 0.70 0.90 1.10 1.30 1.50 1.70 1.90 2.10 2.30 2.50 2.70 2.90
Reset A/B The Reset buttons (recessed in the hole) operate as described below Note
that all LEDs will blink on/off once per second while holding as a way to count the
seconds elapsed.
1) Hold for more than 3 seconds, but less than 6 seconds
a. The IP address will be reset to defaults based on button
i. 192.168.100.100 for Reset “A”
ii. 192.168.100.101 for Reset “B”
b. The CLI management passwords will be reset to default
c. The Web interface passwords will be reset to default.
d. The SNMP read/write/trap community strings will be set to defaults.
e. The CLI prompt will be reset.
2) Hold for more than 6 seconds: The unit will reset the system configuration to
the factory defaults, but NOT reset the items in (1) above. The unit WILL
REBOOT automatically.
a. The TX and RX Frequencies will be reset to allow a link to be established
as follows:
i. TX/RX Frequency of 24.1/24.2 GHz for Reset “A”
ii. TX/RX Frequency of 24.2/24.1 GHz for Reset “B”