User's Manual
Getting Started
Trango Broadband Wireless — User Manual M2400S Rev. A
Page
6
Several functions, such as the site survey function and the SU RSSI function can only be performed
while the radio is in a particular opmode. See Appendix D (Command Set Reference) for a complete
listing of commands, and the appropriate opmode for each command.
Switch Settings
M2400S firmware includes several “switches” which are used to set certain operational parameters of the
radios. Switch settings can be changed via the HTTP browser interface or the Command Line Interface.
For purposes of radio TCP/IP management, the following four switches are important:
Switch 2 (SU) - TCP/IP access to SU from the AP’s side of network requires that the SU’s switch 2
(SW 2 – TCP/IP for AP) be “ON”. Default setting for SW 2 (from factory) is “ON”.
Switch 5 (AP and SU) – In order to utilize the radio’s HTTP Browser interface, switch 5 (SW 5 –
Enable HTTP) must be “ON”. Default setting for SW 5 (from factory) is “ON”.
Switch 6 (SU) - TCP/IP access from Ethernet port of SU while opmode is on, requires that switch 6
(SW 6 – TCP/IP Service for Ethernet Port) be “ON”. Default setting for SW 6 (from factory) is “ON”. If
SW 6 is off, TCP/IP access to SU from it’s Ethernet port is possible only if SU’s opmode is OFF.
Switch 7 (AP) – TCP/IP access to AP from SU’s side of network requires that the AP’s switch 7 (SW 7
– TCP/IP for SU) be “ON”. Default setting for SW 7 (from factory) is “ON”.
Passwords
In order to logon to an M2400S radio (either through telnet or through the web browser interface), the
user must know the IP address and password. Both AP’s and SU’s feature two levels of passwords;
Read Write (RW) and Read Only (RO). Be sure to change both passwords (RW and RO) prior to
deployment of your radios on a live network. Passwords can be changed using the “password ro and
password rw command in either the CLI interface or in the command console of the browser interface.
Reset Button
Pressing the reset button will reset the radio’s IP address and password back to factory defaults.
Default IP (192.168.100.100) Default Password (trango)
Browser Interface
The M2400S (both AP and SU) features a convenient and easy-to-use web based configuration and
management tool. No additional software is needed on your computer other than a web browser. Most
functions can be performed using the browser interface, although several functions can only be
performed using command line interface (CLI). The browser interface also includes a “command
console” page which allows the user to enter most CLI commands without leaving the browser interface.
To use the browser interface – the following must be present:
• An Ethernet connection between a PC and the radio
• Ethernet PC connection with IP/subnet that is routable to the radio
• SW 5 On (default)
• A web browser on the PC (i.e. Microsoft Internet Explorer)
In order to use the browser interface – simply connect the radio to a PC, and type the radio’s IP address
(default IP address=192.168.100.100) into the web browser (i.e. Microsoft Internet Explorer). This will
bring up a login page.
NOTE: Login pages for AP and SU are similar.