Installation and Maintenance Manual
Table Of Contents
- Warnings, Cautions and Notices
- Model Number Descriptions
- General Information
- ECM Application Notes
- Dimensions and Weights
- Receiving and Handling
- Pre-Installation
- Installation—Mechanical
- Installation—Piping
- Installation—Sensors
- Installation—Electrical
- ECM Overview and Setup
- Time Clock
- Wired Controllers—Communication Wiring
- Pre-Start
- Startup
- Tracer ZN520 Unit Startup
- Tracer UC400 Unit Startup
- General Information
- Fan Mode Switch Operation
- Tracer ZN520 Operation
- UC400 Controller Operation
- Tracer ZN520 Sequence of Operation
- UC400 Sequence of Operation
- Power-up Sequence (UC400)
- Random Start (UC400)
- Occupancy Modes (UC400)
- Timed Override Control (UC400)
- Zone Temperature Control (UC400)
- Discharge Air Tempering (UC400)
- Heating or Cooling Mode (UC400)
- Entering Water Temperature Sampling Function (UC400)
- Fan Operation (UC400)
- Exhaust Control (UC400)
- Valve Operation (UC400)
- Modulating Outdoor/Return Air Damper (UC400)
- Two-position Control Of A Modulating Outdoor Air Damper (UC400)
- Electric Heat Operation (UC400)
- Dehumidification Operation (UC400)
- Peer-to-peer Communication (UC400)
- Unit Protection Strategies (UC400)
- Maintenance
- Diagnostics
- Replacing ECM Components

Dimensions and Weights
UV-SVN03F-EN 13
Figure 3. Falseback unit
UNIT SIZE
075
100
125
150
NO. FANS
2
2
4
4
A
69"
81"
93"
105"
B
42"
54"
66"
78"
C
25" to 29"
25" to 29"
25" to 29"
25" to 29"
NOTE:
1. THE UNIT LENGTH DOES NOT INCLUDE 5/8" END PANELS.
2. THE POWER CONNECTION IS MADE IN THE LEFT HAND
END POCKET FOR ALL OPTIONS BUT ELECTRIC HEAT.
3. THE POWER CONNECTION FOR ELECTRIC HEAT OPTION
IS MADE IN THE RIGHT HAND END POCKET.
14 3/8"
21/4"
21/2"
16 5/8"
23/8"
30"
21 1/4"
SIDE VIEW
Depicting Step-down
Falseback
18"
C
STEP-DOWN
IS IN 1"
INCREMENTS
21/4"
21/2"
16 5/8"
23/8"
30"
21 1/4"
SIDE VIEW
18"
5 1/4"
7"
PIPE
CHASE
14 3/8"
11"
9 1/4"
8
"
2
1
1
1
/
2
"
3
3
0
0
"
PIPE
C
HA
S
E
7/8" O.D.
DRAIN CONN.
7/8" O.D.
AUX.
DRAIN CONN.
(optional)
FRONT OF UNIT
RETURN AIR
(OPTIONAL)
FALSEBACK
A
(4)K.O. FOR PIPING
OR ELECTRICAL
5 3/4"
5"
9"
12 1/2"
22 5/8"
21/4"
BACK VIEW
8 1/8"
12 1/4"
B
FRESH AIR OPENING (OPTIONAL)
13 1/2"
3/4"
3 3/4"
STEP-DOWN
FALSEBACK
FOR RETROFIT
APPLICATIONS
WHERE WINDOW
SEAL MAY INTERFERE
WITH UNIT INSTALLATION
(OPTIONAL)
STEP-DOWN
FALSEBACK
4. THE UNIT SHOWN INCLUDES THE INSULATED HORIZONTAL
BAFFLE OPTION.
2"
21/4"
(2)9" x 9"[229mm x 229mm]
KNOCKOUTS IN BOTTOM
10 7/8"
3 3/4"
TOP VIEW
13"
FALSEBACK
UV-SVN03_.book Page 13 Thursday, January 24, 2013 5:27 PM