Catalogue
UV-PRC003-EN 61
Performance Data
Table 45. VUV 150, steam heating coils K (low-capacity), L (high-capacity)
Size Coil
Entering
Air Temp,
Dry Bulb
(°F)
Steam Pressure (psig)
51015
Total
Capacity
(MBh)
Airside
Temp Rise
(°F)
Total
Capacity
(MBh)
Airside
Temp Rise
(°F)
Total
Capacity
(MBh)
Airside
Temp Rise
(°F)
1500 K 0 141.1 87.1 148.4 91.6 154.7 95.5
10 134.8 83.2 142.1 87.7 148.4 91.6
20 128.6 79.4 135.9 83.9 142.2 87.8
30 122.4 75.6 129.7 80.1 136.0 83.9
40 116.2 71.7 123.5 76.2 129.8 80.1
50 110.0 67.9 117.3 72.4 123.6 76.3
60 103.8 64.1 111.1 68.6 117.4 72.5
70 97.6 60.2 104.9 64.8 111.2 68.6
L 0 208.2 128.5 219.0 135.2 228.2 140.9
10 199.0 122.9 209.9 129.5 219.1 135.2
20 189.9 117.2 200.7 123.9 209.9 129.6
30 180.8 111.6 191.6 118.2 200.8 123.9
40 171.6 105.9 182.4 112.6 191.6 118.3
50 162.5 100.3 173.2 106.9 182.5 112.6
60 153.3 94.6 164.1 101.3 173.3 107.0
70 144.1 89.0 154.9 95.6 164.1 101.3
psig = steam pressure (lb/in.
2
gage)
Heating - 150 - Coil K, L
UV-PRC003-EN.book Page 61 Tuesday, June 4, 2013 8:59 PM